KOSUN single phase modified sine wave 1000w power inverter have several protections.
The protection feature(12V input inverter sample):
Input low voltage protection:
When the battery voltage is below 10.5± 0.5V,a buzzer will alarm which indicates DC power supply voltage is descending and batteries need to recharge;
When input voltage is below 10.0±0.5v,AC output will be automatically shut off,a buzzer alarm and ALARM/WARNING light turns red at the same time.
Input over voltage protection:
When input voltage reach 16.0v±0.5v,ALARM/WARNING light turns red and the AC output will be shut off automatically.
Short Circuit protection:
When short circuit occur,output will be shut off and ALARM/WARNING light turns red.
Over load protection:
When overloads occur,output will be shut off and ALARM/WARNING light turns red.
Reverse polarity protection:
When battery terminals are reverse connected,fuse will be burned to protect appliances.
Over temperature protection:
When heat sink temperature exceeds 45℃,the inner cooling fan will automatically turn on to cool the inverter;
When inner temperature exceeds 75℃,AC output will automatically shut off,ALARM/WARNING light turns red.It is unusable for 15 minutes.
Product parameter(Specification) of the 1000w power inverter
Modified Sine Wave Inverter | |||||||
■ Modified sine wave output; ■ High surge power up to 2 times of real loading power; ■ Loading 1.5times rated power for 10s,2times for 2s; ■ High efficiency up to 92%; ■ Power ON-OFF switch; ■ Soft start; ■ Built-out fuse; ■ More stable working functions ■ Front panel indicator for operation status; ■ Thermostatically and load controlled cooling fan; ■ Protections:Bat. low alarm/Bat. low shutdown/Bat. over shutdown/output short/input reverse protection/overload/over Temp. ■ 18 months wattanty | |||||||
MODEL |
KS1000M-112 |
KS1000M-124 |
KS1000M-148 |
KS1000M-212 |
KS1000M-224 |
KS1000M-248 | |
OUTPUT |
RATED POWER |
1000W | |||||
SURGE POWER |
2000W | ||||||
AC VOLTAGE |
Factory setting set at 100V/110V/120V AC |
Factory setting set at 220V/230V/240V AC | |||||
FREQUENCY |
50Hz/60Hz optional | ||||||
WAVE FORM |
Modified sine wave | ||||||
AC REGULATION |
±10% | ||||||
STANDARD RECEPTACLES |
Schuko/UK/Australia/Universal/USA/France/JP/Brazile | ||||||
FRONT PANEL INDICATOR |
Operation and fault status | ||||||
INPUT |
BAT.VOLTAGE |
12V |
24V |
48V |
12v |
24V |
48V |
VOLTAGE RANGE |
9.7-16.4VDC |
19.4-32.8VDC |
38.8-65.6VDC |
9.7-16.4VDC |
19.4-32.8VDC |
38.8-65.6VDC | |
DC CURRENT |
100A |
50A |
25A |
100A |
50A |
25A | |
NO LOAD CURRENT DRAW |
<0.32A |
<0.25A |
<0.2A |
<0.32A |
<0.25A |
<0.2A | |
EFFICIENCY |
89% |
>90% |
92% |
88% |
90% |
91%% | |
BATTERY TYPES |
Recommend use Open & sealed lead acid battery | ||||||
BATTERY INPUT PROTECTION |
BAT.LOW ALARM |
10.8±0.3V |
21.6±0.6V |
43.2±1.2V |
10.8±0.3V |
21.6±0.6V |
43.2±1.2V |
BAT.LOW SHUTDOWN |
10±0.3V |
20±0.6V |
40±1.2V |
10±0.3V |
20±0.6V |
40±1.2V | |
BAT.OVER SHUTDOWN |
16±0.4V |
32±0.8V |
64±1.6V |
16±0.4V |
32±0.8V |
64±1.6V | |
REVERSE POLARITY |
yes | ||||||
OUTPUT PROTECTION |
OVER TEMPERATURE |
≥45ºC or ≥60% rated power, cooling fan open;≥70ºC,Shut off. | |||||
Protection type : Shut down o/p voltage, re-power on to recover; by internal Thermistor detect on heatsink of power transistor | |||||||
OUTPUT SHORT |
Protection type:Shut down o/p voltage;re-power on to recover | ||||||
OVER LOAD |
100%-120% rated load for 10 sec. | ||||||
Protection type : Shut down o/p voltage, re-power on to recover; by internal Thermistor detect on heatsink of power transistor | |||||||
ENVIRONMENT |
WORKING TEMP. |
-15℃~+40℃@100% load;60℃ @50% load | |||||
WORKING HUMIDITY |
20%90% RH non-condensing | ||||||
STORAGE TEMP. |
-30℃~+70℃/-22℉~+158℉ | ||||||
STORAGE HUMIDITY |
10%95% RH non-condensing | ||||||
SAFETY |
CE |
Compliance to EN55032 | |||||
LVD |
Compliance to EN60950-1 | ||||||
ROHS |
Compliance to EN50581 |