Specification
SETUP, RISE, HOLD TIME |
1.5s, 50ms, 15ms/230VAC at full load |
VOLTAGE RANGE |
176 ~264VAC 248 ~ 370VDC |
FREQUENCY RANGE |
47 ~ 63Hz |
POWER FACTOR |
PF>0.95/230VAC at full load |
AC CURRENT |
10.5A/230VAC |
INRUSH CURRENT (max.) |
100A/230VAC |
LEAKAGE CURRENT |
<3.5mA / 240VAC |
OVER LOAD |
115~140% of rate load Protection type : Constant current limiting, recovers automatically after faul |
OVER TEMPERATURE |
OVER TEMPERATURE TSW1: 95?C (Detect on the heatsink of PFC MOSFET) TSW2: 90?C (Detect the winding of |
|
Protection type : Shun down o/p voltage, recovers automatically after temperature goes down |
REMOTE CONTROL |
RC+/RC-: 0 ~ 0.8V=power on ; 4 ~ 10V=power off sink current <30mA |
WORKING TEMP., HUMIDITY |
-10~+65?C (Refer to output load derating curve), 20~90% RH non-condensing |
STORAGE TEMP., HUMIDITY |
-20~+85?C , 10~95% RH |
TEMP. COEFFICIENT |
?0.03%/?C (0~50?C) |
VIBRATION |
10~500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
SAFETY STANDARDS |
UL1950, TUV EN60950 Approved |
EMI CONDUCTION & RADIATION |
Compliance to EN55022 (CISPR22) Class B |
HARMONIC CURRENT |
Compliance to EN61000-3-2,-3, Class A |
EMS IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, Light industry level, criteria A |
WITHSTAND VOLTAGE |
WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
MTBF |
43.4K hrs min. MIL-HDBK-217F (25?C ) |
|