BR-100W HV LASER POWER SUPPLY
Feature
1. Laser power control is simple on this black color Laser Power Supply, you can use 0 ~ 5V analog signal control the laser power, you can also use the PWM (pulse width modulation) signal to control output laser power.
2. Protection function: This high voltage Laser Power Supply has open circuit protection: Under the condition of good protective earth, the black color Laser Power Supply can work in open-circuit for a short time, which could avoid the damage to the 100w Laser Power Supply
3. This Yongli Laser Power Supply adopts G/P/L/G/IN/5V as control signal output interface with black color case.
4. This 100w Laser Power Supply has stable output laser power performance: Each high voltage Laser Power Supply has been much more rigorous testing procedures, under full load high temperature (52~55 degrees Celsius) 24 hours of aging, to ensure the stability of each black color Laser Power Supply.
5. Good compatibility: The Yongli Laser Power Supply can drive Yongli,EFR,SPT,Weiju and other brand 1.4 or 1.5 meter length 100W CO2 laser tube and it also has a strong adaptability and fast response, engraving, cutting advantages of good effect.
6. Control is simple: This high voltage Laser Power Supply uses high or low level control, the use of TTL-level control of the laser can start and stop. At the same time it increases the protection switch, testing is through the external water and ventilation on the 100w Laser Power Supply
Specification
lnput |
Input voltage |
AC220V±10% (AC110V specified while order) |
||
|
AC frequency |
47~440HZ |
||
|
Maximum input power |
770W |
||
|
Maximum input current |
3.5A |
||
Output |
Maximum output voltage |
35KV |
||
|
Maximum output current |
33mA (depending on the laser tubes of different manufacturers) |
||
Efficiency |
More than 90% (Full load) |
|||
Response speed |
Not more than 1ms |
|||
Control lnterace |
TTL multilevel switching control,effective level can be high and low selection (see control wining diagram) |
|||
Insulation |
lnput-output |
AC 1500V 1 minutes not more than 10mA |
||
|
lnput-shell |
AC 1500V 1 minutes not more than10mA |
||
|
Output-shell |
Connection |
||
Open Circuit Protection |
Can be short circuit (requires a good grounding shell,while avoiding the positive electrode and the shell between the arc) |
|||
Environmental Requested |
Working temperature |
-10 ℃~50 ℃ |
||
|
Storage of temperature |
-20 ℃~75 ℃ |
||
|
Relative Humidity |
Maximum 85%RH (non-condensing) |
||
|
Altitude |
100,000 feet of work 200,000 feet of storage,dose not work |
||
Cooling methods |
Forced air cooling (fan cooling) |
|||
Dimensions (LxWxH) |
305mmx205mmx112mm |
|||