1.Note For Use Of Battery
For this specification, the battery pack consists of 4 single-cell,1300mAH battery series connection,voltage is 12.8V and the total capacity is 1300mAh.
Standard charge: Constant Current 650mA(0.5C), end Voltage 14.6V, 26mA cut-off, Approx 2.5h.
Standard discharge: Constant current 650mA(0.5C),end voltage 9.2V,
Fast charge: Constant Current 1300mA(1.0C),end Voltage 14.6V,26mA cut-off,Approx 1.5h
Operation Temperature Range: Charge at 0~40℃,Discharge at -10~70℃(60±25%R.H.Bare Cell)
Storage Temperature Range: Less than 1 year: -10~20℃,Less than 1 year: -10~20℃( 60±25%R.H.at the shipment state)
2.Handling of Cells
Cell fixing
The cell should be fixed to the battery pack by its large surface area.No cell movement in the battery pack should be allowed.
Inside design
No sharp edge components should be insides the pack containing the LIP cell.
3.Other notice
Prohibition of disassembly
1)Never disassemble the cells.The disassembling may generate internal short circuit in the cell, which may cause gassing, firing, explosion, or other problems
2)Electrolyte is harmful.Battery should not have liquid from electrolyte flowing, but in case the electrolyte come into contact with the
skin, or eyes, physicians shall flush the electrolyte immediately with fresh water and medical advice is to be sought.
Prohibition of dumping of cells into fire
Prohibition of dumping of cells into fire
Never incinerate nor dispose the cells in fire. These may cause explosion of the cells, which is very dangerous and is prohibited.
Battery cells replacement.
Battery cells replacement
The battery replacement shall be done only by either cells supplier or device supplier and never be done by the
user.
Please do not exceed the specification range using the battery
5.