Home
/
Categories
/
Electrical Equipment & Supplies
/
Batteries
/
Rechargeable Batteries
/
4IFR19/66 Huahui New Energy Secondary Super Li-ion Battery
4IFR19/66 Huahui New Energy Secondary Super Li-ion Battery
FOB Price USD 35 USD / set
MOQ
100 / set
Port
shenzhen
Lead Time
15 working days
China
Main Products : Lithium Iron battery, Lithium Titanate battery, Ultra small size battery, Rechargable Lithium battery
7th Tongziba Lane,Jinxiu Road Yiyang, Hunan
4IFR19/66 Huahui New Energy Secondary Super Li-ion Battery Details
Brand Name
Huahui
Model Number
4IFR19/66
Place of Origin
China
Battery Type
Lithium
Nominal Capacity
1300mAh
Nominal Voltage
12.8V
Size
38*38*70mm
Type
Rechargeable battery
Standard Charge
0.5C around 2.5h
Standard Discharge
0.5C
4IFR19/66 Huahui New Energy Secondary Super Li-ion Battery Introduce

1.Note For Use Of Battery

For this specification, the battery pack consists of 4 single-cell,1300mAH battery series connection,voltage is 12.8V and the total capacity is 1300mAh.

Standard charge: Constant Current 650mA(0.5C), end Voltage 14.6V, 26mA cut-off, Approx 2.5h.

Standard discharge: Constant current 650mA(0.5C),end voltage 9.2V,

Fast charge: Constant Current 1300mA(1.0C),end Voltage 14.6V,26mA cut-off,Approx 1.5h

Operation Temperature Range: Charge at 0~40℃,Discharge at -10~70℃(60±25%R.H.Bare Cell)

Storage Temperature Range: Less than 1 year: -10~20℃,Less than 1 year: -10~20℃( 60±25%R.H.at the shipment state)

2.Handling of Cells

Cell fixing

The cell should be fixed to the battery pack by its large surface area.No cell movement in the battery pack should be allowed.

Inside design

No sharp edge components should be insides the pack containing the LIP cell.

3.Other notice

Prohibition of disassembly

1)Never disassemble the cells.The disassembling may generate internal short circuit in the cell, which may cause gassing, firing, explosion, or other problems

2)Electrolyte is harmful.Battery should not have liquid from electrolyte flowing, but in case the electrolyte come into contact with the

skin, or eyes, physicians shall flush the electrolyte immediately with fresh water and medical advice is to be sought.

Prohibition of dumping of cells into fire

Prohibition of dumping of cells into fire

Never incinerate nor dispose the cells in fire. These may cause explosion of the cells, which is very dangerous and is prohibited.

Battery cells replacement.

Battery cells replacement

The battery replacement shall be done only by either cells supplier or device supplier and never be done by the

user.

Please do not exceed the specification range using the battery

5.