Product Introduction
In response to a high torque and speed controlFor fast start-stop, suddenly loading and unloading of the occasionMutation load, the torque limiter function of mechanical protectionPearl wave restriction functionCan effectively prevent an overcurrent warning or interference caused by a sudden load, thereby protecting the safety device.Tracking speed smooth startRich fault protection and operation monitoring functionDiverse controlExcellent current control ability, to ensure that the rapid acceleration process does not trip operation, and the acceleration time is shorterPowerful overload suppression ability to ensure that the inverter will not stop due to overload faults at the maximum output;
Solutions
1. Inverter automatically working
When the input DC voltage lower than 230V, the inverter will turn to dormancy.
It will automatically wake up and working once input DC voltage higher than 230V.
2. Dry-run function with three solutions
1) Dry-run function without sensor.
2) Analog sensor detect Water function.
Solar Panel Configure
In the case of not exceeding the maximum input voltage, the greater the power the better, the greater the voltage the better.
① Configure Solar panel power: 1.3 times of Pump’s power.
② Arranged solar panel voltage: 220V inverter board recommended Voc 360 ~ 430VDC, 380V inverter board recommended Voc 600 ~ 750VDC.
③ Solar panel output current: solar panel’s Imp> Motor rated current
Input specication | ||
Model | PV150-2S | PV150-4T |
PV500-4T | ||
Maximum Input DC Voltage | 450VDC | 800VDC |
Re commended Voc Range | 360~430VDC | 600~750VDC |
Re commended MPPT Voltage Range | 250~350VDC | 450~600VDC |
Starting Voltage Range | PV150:80~450VDC | 230~800VDC |
Grid or backup generator input | ||
Input voltage | 2S: Single phase 220V(-15%~20%) | Three phase 380V(-15%~30%) |
Output specication | ||
Rated output voltage | 3PH 220V | 3PH 380V |
Output frequency | 0~600.00Hz (default: 0~50.00Hz) | 0~600.00Hz (default: 0~50.00Hz) |
Protection | ||
Built-in Protection | Lighting Protection, over-current,overvoltage,output phease-lose,under-load, under-voltage,short circuit, overheating, water pump run dry etc. | Lighting Protection, over-current,overvoltage,output phease-lose,under-load, under-voltage,short circuit, overheating, water pump run dry etc. |
General Parameters | ||
Application Site | No direct sunshine, no dust,cirrisuve gas, combustible gas, oil mist, steam, dripping or salinity etc. | |
Altitude | 0~2000m Derated use above 1000m, per 100m, the rated outed output currentdecrease 1% | |
Environment Temperature | -10°C~40°C (Environment Tenmperature be 40°C~50°C, please keep derated use.) | |
Humidity | 5~95% non-condensation | |
Vibration | less than 5.9 m/s² (0.6g) | |
Storage Temperature | -20°C~+70°C | |
Effciency | Rated Power Run ≥93% | |
Installation | Wall or rail mounting | |
Protection Grade | IP20 | |
Cooling | Forced Air Cooling |