Home
/
Categories
/
Electrical Equipment & Supplies
/
Wires, Cables & Cable Assemblies
/
Power Cables
/
ASTM Low Voltage Power Cable , Aluminum PVC 120mm 4 Core Cable 1kV
ASTM Low Voltage Power Cable , Aluminum PVC 120mm 4 Core Cable 1kV
FOB Price
China
Main Products : PVC Insulated Power Cable
Room 1 Floor 1 Wire and Cable Manufacturing Bare Wire Workshop 1 Wujin Industrial Park, Dongjing Street, Hannan District, Wuhan City Wuhan, Hubei
ASTM Low Voltage Power Cable , Aluminum PVC 120mm 4 Core Cable 1kV Details
Place of Origin
China
Supply Type
OEM Service
Condition
New
ASTM Low Voltage Power Cable , Aluminum PVC 120mm 4 Core Cable 1kV Introduce

Detailed Product Description

High Light:

Aluminum 120mm 4 Core Cable

, 

ASTM Low Voltage Power Cable

, 

PVC 120mm 4 Core Cable

Aluminum Core Low Voltage Power Cable ASTM PVC 120mm 4 Core Cable 1kVApplication

This product is suitable for power lines with rated voltage of 0.6 / 1kV and below, for power transmission, suitable for laying in hotels, stations, airports, high-rise buildings, chemical industry, petroleum platform, power station, subway, tunnel and other fixed laying places.

Application Performance

The long-term allowable operating temperature of the cable shall not exceed 70℃, and the short-time working temperature shall not be over 130℃.

The ambient temperature of the installation should not be lower than 0℃.

Minimum bending radius during cable installation: single-core cable not exceeding 20D (D is cable diameter), multi-core cable not exceeding 15D (D is cable diameter)

Cable ConstructionConductor adopts compact shaped or compact circular structure.

3.2 70℃ PVC insulation material is used for insulation, and the insulation thickness is shown in Table 1.

Table 1

Nominal section mm2Nominal thickness of the insulation mmNominal section mm2Nominal thickness of the insulation mm
1.5 2.50.81501.8
4 61.01852.0
10 161.02402.2
25 351.23002.4
50 701.44002.6
95 1201.6  

3.3 The sheath is made of 70℃ PVC sheath material.

3.4 Nominal outer diameter and weight

Table 2

specifications

Core * section

Reference to outer diameter mm

Nominal weight

kg / km

specifications

Core * section

Nominal outer diameter mmNominal weight kg / km
CuALCUAl
1*1.55.851422*1.510.2128109
1*2.56.264492*2.511.0158127
1*47.188642*412.7219170
1*67.6111752*613.8272200
1*108.6158972*1015.8383262
1*169.62201242*1617.8528335
1*2511.23251722*2521.0773466
1*3512.04172082*3522.6980556
1*5013.75532692*5026.71299725
1*7015.67643542*7030.31776947
1*9517.610314612*9534.524001248
1*12019.212745562*12037.529451494
1*15021.215636722*15041.736331832
1*18523.419438292*18546.145162266
1*24026.2253210552*24051.758692886
1*30029.0315212962*30057.172763527
1*40032.5399416262*40064.392584475
3*1.510.71541254*1.511.5183146
3*2.511.51941484*2.512.4236174
3*413.42742014*414.5337240
3*614.53472394*615.8431287
3*1016.84973154*1018.3625382
3*1618.96984074*1620.7886498
3*2522.410355744*2524.61324709
3*3524.113286924*3526.51709861
3*5027.817689074*5030.822961148
3*7031.9245012074*7035.331851529
3*9536.4332515984*9540.443312028
3*12039.6409319174*12044.053372435
3*15044.1505123504*15049.866463044
3*18549.5631729424*18555.182623762
3*24055.5822437494*24061.8107634796
3*30061.51024046164*30068.5134025904
3*40069.01298458104*40077.1170347468
3*2.5+1*1.512.22231683*2.5+2*1.512.9254189
3*4+1*2.514.03112233*4+2*2.514.8354250
3*6+1*415.54082763*6+2*416.5474318
3*10+1*617.65763583*10+2*618.8664410
3*16+1*1020.18214693*16+2*1021.5955543
3*25+1*1623.612146563*25+2*1625.21409755
3*35+1*1625.115017683*35+2*1626.51694865
3*50+1*2529.3205410393*50+2*2531.823771208
3*70+1*3533.1280513513*70+2*3535.832401574
3*95+1*5038.1382818143*95+2*5041.143922091
3*120+1*7041.9480422143*120+2*7045.656072603
3*150+1*7046.4576926543*150+2*7049.065373007
3*185+1*9551.6727533243*185+2*9554.883283801
3*240+1*12057.6953943383*240+2*12061.0108454919
3*300+1*15063.91169751733*300+2*15067.7133045879
3*400+1*18571.51478864883*400+2*18575.7167837358
4*2.5+1*1.513.22671965*1.512.3215168
4*4+1*2.515.23792675*2.513.4279203
4*6+1*416.84983305*415.7403282
4*10+1*619.37134335*617.1519340
4*16+1*1022.110205725*1019.9759455
4*25+1*1626.115198085*1622.61082598
4*35+1*1627.819019565*2526.91625856
4*50+1*2533.4263513335*3529.321171057
4*70+1*3537.7360317355*5034.728711436
3*95+1*5043.3491523255*7039.739781907
4*120+1*7047.6616428495*9545.554282549
4*150+1*7052.2741133955*12049.566843057
4*185+1*9558.0931442395*15055.382743771
4*240+1*12064.71225455625*18561.1102834659
4*300+1*15071.81500666075*24068.5133965938
3*400+1*18580.61902583335*30075.9166817309
    5*40085.6212409282

Main performance

4.1 The DC resistance of 20℃ conductor shall meet the requirements of Table 3.

Table 3

nominal cross mm21.52.5461016253550
20℃ conductor DC resistance is not over than (Ω / km)Cu12.17.414.613.081.831.170.7270.5270.387
Al 12.47.414.613.081.911.200.8680.641
nominal cross mm27095120150185240300400 
20℃ conductor DC resistance is not greater than (Ω / km)copper0.2680.1930.1530.1240.09910.07540.06010.0470 
aluminium0.4430.3200.2530.2060.1640.1250.1000.0778 

4.2 Finished cable shall be subjected to 3.5kV / 5min voltage test without breakdown.