Human body composition analyzer is the most complex machine in the world, and we know little about it. Many of
us think that we are young and have good health. In fact, in today 's cities, tense rhythm of urban
life, heavy work and study pressure, long-term irregular life, poor eating habits, poor sleep quality,
lack of exercise and other factors are affecting our health slowly, however, we do not notice the
changes in the physiology and function of the body. When we find the problems of our body
before going to the hospital for examination, we often have missed the best time for treatment.
Knowing yourself is good for you. Physical fitness is a comprehensive reflection of human
body shape and function, and is an important basis for health. For modern people in sub-health
status, frequent testing of physical fitness is helpful to understand their own health status, so as to
select the course of physical weight loss, carry out exercise and disease prevention.
Body 270 Body Composition Testing Analyzer uses the principle of multi-frequency
bioelectrical impedance testing and point touch electrode method to measure the bioimpedance of
various parts of the human body, detect various components of the human body, and analyze the
health status of the human body (including: body weight, protein, fat, water, inorganic salts,
waist-to-hip ratio, etc.). It can provide scientific and effective data for weight control, weight loss,
slimming, muscle training, nutritional balance and diagnosis of diseases. This instrument has the
functions of body composition analysis, muscle fat analysis, obesity analysis and health
assessment. It is widely applicable to many fields such as hospitals, rehabilitation centers,
bodybuilding and weight loss slimming centers, sports and fitness clubs.I. Preparation before operation
1. Check that the power supply voltage is consistent with this instrument, and the power
supply must have a good and safe grounding device and leakage protection switch.
2. Insert the two handles into each side of the host machine post and hang them according to
the product diagram.
3. Connect the host machine power cord.
4. Inspect the pedestal assembly and keep it clean and do not place any weight objects on it.
II. Correct use of instruments
1. Startup limit: After turning on the power switch, the system initializes and enters the
standby state after about 30 seconds, and the screen displays the interface as shown in Figure 1.
Enter the correct password (default password: 000000, click "Change Password" to reset the
password and then enter the main interface (Figure 2).2. Test function: Click the "Test" button in the main interface (Figure 2) to enter the test
function interface (Figure 2). Left is a list of all test customers. Click on the customer name to
select the customer.3. Add customers: Click the "Add" button in
the test function interface to enter the customerdata editing interface (Figure 4).
(1) Click the input box below "ID" to input the customer ID, which is the unique customer ID
and cannot be repeated with other customer ID.
(2) Click the "Age" entry box to enter the midday age, with range of 10 ~ 99 years.
(3) Click the "Gender" entry box to enter gender, M for male and F for female.
(4) Click the "Height" input box to input the height, with the height range of 90 ~ 220 cm.
(5) Click "Next" to add new customers when all information has been entered. After
successful creation, you will enter the weight test interface (Figure 5)4. Weight test: After selecting a customer or adding a new customer (Figure 4) in the test
function interface (Figure 3), it will enter the weight test interface (Figure 5). Standing on
pedestal , click on the "Test-retest" button to start the weight measurement.
5. Preparation test: After the completion of weight test, click "Next" to enter the preparation
test interface (Figure 6). Follow interface prompts to complete test preparation.
6. Started test: Click "Next" after preparation to start testing body composition and enter the
test interface (Figure 7). The character color change in the figure indicates the current test
progress. 7. Test details: After the completion of the test, it will enter the test results interface (Figure
8). The test details are divided into 4 categories. Click the label below the interface to switch andview other test data.
8. Print test results: Click the "Print" button in the test details interface (Figure 8). The test
details can be printed, as shown in Figure 9, and the user can select the internal printer or external
printer. 9. Viewing function: After selecting the customer ID in the Test function interface (Figure III),
click the "View" button to enter the viewing function interface (Figure 10). All test records for the
selected customer can be viewed in this interface. Click the entry to select the record, click 'View"
button to enter the test details interface (Figure 8) and view the detailed data. Click the "Delete"
button to delete this test record and the record will not be recoverable once deleted, be careful.
Click the "Test" button to enter the weight testing boundary surface (Figure 5) to perform the new
test.
10. Delete customer: Click the "Delete" button after selecting the customer ID in the test
function interface (Figure 3) and it will pop up the prompt box (Figure 2). Select "Confirm" to
delete this customer and all the test records of this customer. Please operate carefully11. Customer search: When there are many customers in the left list in the test function
interface (Figure 3), click the "Search" button to quickly find the customer using the search
function (Figure 12), enter the customer ID or the number and letter containing the ID, and then
click the "Confirm" button to search the customer.
12. Basic Settings: Click the "Basic Settings" button in the main interface (Figure 2) to enterthe Settings interface (Figure 13).
(1) Language setting: Simplified Chinese and English.
(2) Time setting: 24 hour clock, drag the pulley to set.
(3) Length Unit: Click "feet" or "cm" to convert the display unit.
(4) Speaker: Click the icon to turn the speaker on or off. Note: For some models without
speakers, this function is invalid.
(5) WI-F1: Click on the icon to access the Wi-Fi connection screen. Note: This feature is
only used when updating the external printer drive.
(6) Click the "Confirm" button to save the setup results.