Home
/
Categories
/
Measurement & Analysis Instruments
/
Testing Equipment
/
Biological Safety Cabinet_PURICUBE NEO
Biological Safety Cabinet_PURICUBE NEO
FOB Price
Korea (North)
Main Products : biological safety cabinet, centrifuge, autoclave
397 Seokcheon-ro Ojeong-gu, Bucheon-si, Gyeonggi-do
Biological Safety Cabinet_PURICUBE NEO Details
Place of Origin
Korea
Supply Type
In-Stock Items
Condition
New
Biological Safety Cabinet_PURICUBE NEO Introduce

Class ll type A2 biological safety cabinet that protects the user and lab environment from the biohazard factor and prevents cross contamination of various samples used in experiments

[STANDARD SPECIFICATION]

-> Model : PURICUBE NEO 900 / PURICUBE NEO 1200 / PURICUBE NEO 1500 / PURICUBE NEO 1800

-> Inner(W x D x H)mm : 900x576x649 / 1200x576x679 / 1500x576x679 / 1800x576x663

-> Out(W x D x H)mm : 970x783x2100 / 1270x783x2100 / 1570x783x2100 / 1870x783x2100

-> Type : Class Ⅱ A2 (70% recirculation as downflow & 30% exhaust as outflow)

-> Filter : H-14 HEPA filter : 99.995% at 0.3㎛ / ISO class 5

-> Average Airflow Velocity Inflow : 0.40 m/s / 0.40 m/s / 0.40 m/s / 0.40 m/s

-> Average Airflow Velocity Downflow : 0.30 m/s / 0.30 m/s / 0.30 m/s / 0.30 m/s

[MAIN FEATURE]

-> Ergonomic design to give the increased convenience

- With a 10 degrees sloped design, it is possible to reduce tension in the arms, neck, and shoulders during the experiment. - Thanks to higher door glass, extensive visibility can be achieved. Since there is no frame at the bottom of the door glass, the visibility is not disturbed during experiment. - Due to the armrest, it is convenient to perform more than a certain amount of time, and the elbow can be fixed in the event of precise operation

- ① ∠10° Angle in front

- ② Frame-less window

-> Strengthen validation support using higher performance filters

- HEPA filter that enables to remove 99.995% of particles that have a size greater than or equal to 0.3㎛ - Optional ULPA filter that enables to remove 99.9995% of particles that have a size greater than or equal to 0.12㎛

-> Equipment that enables safe UV sterilizer

- UV sterilization will effect micro organisms at the surface of work table. - While UV light is on, front reinforcement glass door protects the user by blocking UV rays. - Automatically turns off UV light when opening the door or turning on the fluoresent lamp.

-> Checking the life and performance of filters through a differential pressure gauge

Measure the pressure of the bottom HEPA filter to check the performance and lifespan of the filter in real time, allowing more safe and efective testing.