BR-60W CO2 POWER SUPPLIES
Feature
1 .Both analog signals of 0 to 5V and PWM signals are used to control and regulate this AC110V CO2 power supply’ s output laser power.
2 .This AC110V CO2 power supply can adopts ether external LCD digital display module by network cable,which can show HV carbon dioxid power supply’ s working current,working statues and failure code. It is very good function for both machine factory and machine users
3 .This BR-60W CO2 power supply uses ordinary H/L/P/G/IN/5V terminal block to input laser control signal and black steel case.
4 .This LCD screen CO2 power supply has high efficiency and quick response with its zero current half bridge soft switching circuit. Thus it is easy to cooperate with most brand 60W co2 laser tube.
5 .This 60W CO2 laser power supply terminal control is simple and adapted to high and low level signals. TTL 1 level can be used to control the start and stop of laser power. At the same time, an abnormal protection switch was added to detect if the external water is ventilated or not.
6.The HV carbon dioxide power supply use one PCS fan for cooling. It use Japan ’s bearing and make the fan works for very long time.
6 .This HV carbon dioxide power supply has good grounding protection5.With advanced open circuit protection, the 60W CO2 power supply can work in an open-circuit state for a short time, which can avoid the damage of the LCD screen CO2 power supply caused by the bursting of the laser tube.
Specification
lnput |
Input voltage |
AC220V ±10% (AC110V specified while order) |
||
AC frequency |
47~440HZ |
|||
Maximum input power |
490W |
|||
Maximum input current |
2.2A |
|||
Output |
Maximum output voltage |
25KV |
||
Maximum output current |
28mA (depending on the laser tubes of different manufacturers) |
|||
Efficiency |
More than 90% (Full load) |
|||
Response speed |
Not more than 1ms |
|||
Control lnterace |
TTL multilevel switching control,effective level can be high and low selection (see control wining diagram) |
|||
Insulation |
lnput-output |
AC 1500V 1 minutes not more than 10mA |
||
lnput-shell |
AC 1500V 1 minutes not more than10mA |
|||
Output-shell |
Connection |
|||
Open Circuit Protection |
Can be short circuit (requires a good grounding shell,while avoiding the positive electrode and the shell between the arc) |
|||
Environmental Requested |
Working temperature |
-10 ℃~50 ℃ |
||
Storage of temperature |
-20 ℃~75 ℃ |
|||