Home
/
Categories
/
Electrical Equipment & Supplies
/
Other Electrical Equipment
/
Capacitance Loss and Tan Delta Test Machine for Insulation Materials
Capacitance Loss and Tan Delta Test Machine for Insulation Materials
FOB Price 100 USD / Piece
MOQ
1 Piece
Port
ShenZhen
Lead Time
8-12working days after finish the payment
China
Main Products : electrical measurement instrument
Room 801, Dongxing Technology Building, Xincheng Technology Industrial Park,gaoling District Xian, Shanxii
Capacitance Loss and Tan Delta Test Machine for Insulation Materials Details
Brand Name
XZH
Model Number
XHJS1000R
Place of Origin
China
Supply Type
OEM Service
Condition
New
Color
black
Product name
Insulation Oil Dielectric Loss and Resistivity Tester
Name of product
Dielectric Loss Testing Equipment
Item
Transformer Oil Dielectric Loss Tester
Capacitance Loss and Tan Delta Test Machine for Insulation Materials Introduce

The XHJS1000 inter-frequency dielectric loss tester is a high-precision test instrument for testing the dielectric loss tangent and capacitance of various high-voltage power equipment in power plants substations. The instrument is an integrated structure, built-in dielectric loss test bridge, variable frequency voltage regulator, step-up transformer and SF6 high stability standard

capacitor. The test high voltage source is generated by the inverter inside the instrument and is used for testing the test object after being boosted by the transformer. The frequency can be changed to 50Hz, 47.5Hz\52.5Hz, 45Hz\55Hz, 60Hz, 57.5Hz\62.5Hz, 55Hz\65Hz. The digital notch technology is used to avoid the interference of the power frequency electric field to the test, which fundamentally solves the problem. The problem of accurate measurement under strong electric field interference. At the same time, it is suitable for the occasion of power supply detection after power failure. The instrument is equipped with an insulating oil cup and a temperature control device to test the dielectric loss of the insulating oil.

Specifications1. Conditions of use -15°C-40°C RH<80%

2. Anti-interference principle

3. Power supply AC 220V±10% Allowed generator

4. High voltage output 0.5KV - 12KV every 0.1kV Accuracy 2% Maximum current 167mA Capacity 2000VA

5. Self-excited power supply AC 0V∽50V/15A 50HZ, 60HZ single frequency 45HZ/55HZ 47.5HZ/52.5HZ

55HZ/65HZ 57.5HZ/62.5HZ Automatic double frequency conversion

6.Points resolution tgδ: 0.001% Cx: 0.001pF

7.Accuracy △tgδ: ± (reading *1.0%+0.040%) △C x :± (reading *1.0%+1.00PF)

8.Measuring range tgδ Unlimited C x: 15pF < Cx < 300nF

12KV Cx < 300 nF

5KV Cx < 150 nF

1KV Cx < 300 nF

CVT test Cx < 300 nF

9. CVT ratio range 10-10000

CVT ratio accuracy 0.1%

CVT ratio resolution 0.01

10. Dimensions (host) (mm) 350 (L) × 270 (W) × 270 (H)

Dimensions (accessory box) (mm) 350 (L) × 270 (W) × 160 (H)

11. Memory size 200 groups Support U disk data storage

12. Weight (host) 22.75Kg

Previous : NA23 Type Impulse Peak-Voltmeter Next : PSP Series High Precision Programmable Switching Mode DC Power Supply