Home
/
Categories
/
Telecommunications
/
Fiber Optic Equipment
/
Cisco Compatible QSFP DD DR4 400Gbps 500m MPO MTP SMF Optical Transceiver
Cisco Compatible QSFP DD DR4 400Gbps 500m MPO MTP SMF Optical Transceiver
FOB Price
China
Main Products : 400G QSFP DD Transceivers
Room 401 4/F Building 16 Optics valley new power ,high-tech 5th road ,East Lake New technology development zone, Wuhan Hubei city China. Wuhan, Hubei
Cisco Compatible QSFP DD DR4 400Gbps 500m MPO MTP SMF Optical Transceiver Details
Place of Origin
China
Supply Type
OEM Service
Condition
New
Cisco Compatible QSFP DD DR4 400Gbps 500m MPO MTP SMF Optical Transceiver Introduce

Cisco compatible QSFP-DD DR4 MPO/MTP 400Gbps 500m SMF Optical TransceiverQSFP-DD DR4 S-QD4A31M05-CD-4 230301.pdf Ordering informationPart NumberProduct DescriptionS-QD4A31M05-CD-4QSFP-DD 400G 1310nm DR4 500M SMF MPO, 0ºC~+70ºC, With DDM DescriptionSpringtek 400Gb/s QSFP-DD DR4 optical module designed for 500m optical communication applications. S-QD4A31M05-CD-4 module converts 8 channels of 50Gb/s (PAM4) electrical input data to 4 channels of parallel optical signals, each capable of 100Gb/s operation for an aggregate data rate of 400Gb/s. Reversely, on the receiverside, the module converts 4 channels of parallel optical signals of 100Gb/s each channel for an aggregate data rate of 400Gb/s into 8 channels of 50Gb/s (PAM4) electrical output data.An optical fiber cable with an MTP/MPO-12 connector can be plugged into the Springtek 400Gb/s QSFP-DD DR4 module receptacle.Proper alignment is ensured by the guide pins inside the receptacle.The cable usually cannot be twisted for proper channel to channel alignment.Electrical connection is achieved through an QSFP-DD MSA-compliant edge type connector.The product is designed with form factor, optical/electrical connection and digital diagnostic interface according to the QSFP-DD Multi-Source Agreement FeaturesQSFP-DD MSA compliantParallel 4 Optical LanesIEEE 802.3bs 400G-DR4 Specification compliantUp to 500m transmission on single mode fiber (SMF) with FECOperating case temperature: 0 to 70oC8x53.125Gb/s electrical interface(400GAUI-8)Data Rate 106.25Gbps (PAM4) per channel.Maximum power consumption 12WMPO-12 connectorRoHS compliantApplications400G EthernetInfiniband interconnectsData Center Enterprise networking Absolute Maximum RatingsIt hasto be noted that the operation in excess of any individual absolute maximum ratings might cause permanent damage to this module.ParameterSymbolMinTypMaxUnitPower Supply VoltageVcc-0.5 3.6VStorage Temperature RangeTs-40 85°COperating Case TemperatureTo0 70°CRelative Humidity (non-condensation)RH0 85% Recommended Operating Conditions and Power Supply RequirementsParameterSymbolMinTypicalMaxUnitsNotesOperating Case TemperatureTOP0 70degC Power Supply VoltageVCC3.1353.33.465V Data Rate, each Lane 26.5625 GBdPAM4Data Rate Accuracy -100 100ppm Pre-FEC Bit Error Ratio 2.4x10-4 Post-FEC Bit Error Ratio 1x10-12 1Link DistanceD0.002 500m2 Electrical CharacteristicsThe following electrical characteristics are defined over the Recommended Operating Environment unless otherwise specified.ParameterTest ointMinTypicalMaxUnitsNotesPower Consumption 12W Supply CurrentIcc 3.64A Transmitter (each Lane)Signaling Rate, each LaneTP126.5625 ± 100 ppmGBd Differential pk-pk Input Voltage ToleranceMismatchTP1a900 mVpp1Differential TerminationTP1 10% Differential Input Return LossTP1IEEE 802.3-2015Equation (83E-5) dB Differential to Common ModeInput Return LossTP1IEEE 802.3-2015Equation (83E-6) dB Module Stressed Input TestTP1aSee IEEE 802.3bs120E.3.4.1 2Single-ended VoltageTolerance Range (Min)TP1a-0.4 to 3.3V Near-end Eye Height, DifferentialTP1-350 2850mV3Receiver (each Lane)Far-end Eye Height, DifferentialTP426.5625 ± 100 ppmGBd Differential Peak-to-PeakOutput VoltageTP4 900mVpp AC Common Mode Output Voltage (Vcm)TP4 17.5mV Differential TerminationMismatchTP4 10% Differential Output Return Loss TP4IEEE 802.3-2015Equation(83E-2) Common to Differential Mode ConversionReturn LossTP4IEEE 802.3-2015Equation(83E-3) Transition Time, 20% to 80% TP49.5 ps Near-end Eye Symmetry Mask Width(ESMW)TP4 0.265 UI Near-end Eye Height,DifferentialTP470 mV Far-end Eye Symmetry Mask Width(ESMW)TP4 0.2 UI Far-end Eye Height,DifferentialTP430 mV Far-end Pre-cursor ISI RatioTP4-4.5 2.5% Common Mode Output Voltage (Vcm)TP4-350 2850mV3Notes:1. With the exception to IEEE 802.3bs 120E.3.1.2 that the pattern is PRBS31Q or scrambled idle.2. Meets BER specified in IEEE 802.3bs 120E.1.1.3. DC common mode voltage generated by the host. Specification includes effects of ground offset voltage. Optical CharacteristicsParameterSymbolMinTypicalMaxUnitsNotesCenter Wavelengthλc1304.513101317.5nm TransmitterData Rate, each Lane 53.125 ± 100 ppmGBd Modulation Format PAM4 Side-mode Suppression RatioSMSR30 dB Average Launch Power, each LanePAVG-2.9 4dBm1Outer Optical Modulation Amplitude(OMAouter),each LanePOMA-0.8 4.2dBm2Launch Power in OMAouter minusTDECQ, each Lanefor ER ≥ 4.5dBfor ER < 4.5dB -2.2-1.9 dB Transmitter and Dispersion Eye Clouser forPAM4, each LaneTDECQ 3.4dB TDECQ – 10*log10(Ceq), each Lane 3.4dB3Extinction RatioER3.5 dB Difference in Launch Powerbetween any Two Lanes(OMAouter) 4dB RIN15.6OMARIN -136dB/Hz Optical Return Loss ToleranceTOL 21.4dB Average Launch Power ofOFF Transmitter, each LanePoff -26dBm Transmitter Transition Time 17ps Average Launch Power of OFFTransmitter, each LanePoff -15dBm ReceiverData Rate, each Lane 53.125 ± 100 ppmGBd Modulation Format PAM4 Damage Threshold, each LaneTHd5 dBm4Average Receive Power, each Lane -5.9 4dBm5Receive Power (OMAouter), each Lane 4.2dBm Receiver Sensitivity (OMAouter),each LaneSEN Equation(1)dBm6Stressed Receiver SensitivitySRS -1.9dBm7Receiver ReflectanceRR -26dB LOS AssertLOSA-15 dBm LOS De-assertLOSD -8.9dBm LOS HysteresisLOSH0.5 dB Stressed Conditions for Stress Receiver Sensitivity (Note 7)Stressed Eye Closure forPAM4 (SECQ), Lane under Test 3.4 dB SECQ – 10*log10(Ceq), Lane nder Test 3.4dB OMAouter of each Aggressor Lane 4.2 dBm Digital Diagnostic FunctionsThe following digital diagnostic characteristics are defined over the normal operating conditions unless otherwise specified.ParameterSymbolMinMaxUnitsNotesTemperature monitor absolute errorDMI_Temp-33degCOver operatingtemperature rangeSupply voltage monitor absolute errorDMI _VCC-0.10.1VOver full operatingrangeChannel RX power monitor absolute errorDMI_RX_Ch-22dB1Channel Bias current monitorDMI_Ibias_Ch-10%10%mA Channel TX power monitor absolute errorDMI_TX_Ch-22dB1Notes:1. Due to measurement accuracy of different fibers, there could be an additional +/-1 dB fluctuation, or a +/- 3 dB total accuracy.

Previous : Optical Fiber Next : Mellanox MSB7800-ES2F InfiniBand EDR 100Gb/S Switch System 36 QSFP28 Ports 1U
Copyright 2023-2024 - www.globalbiz8.com All Rights Reserved