New
Span drift
1%
Zero drift
1%
Work principle
DOAS
Signal output
4-20mA/RS485/RS232
Continuous Emission Monitoring System/CEM System/Flue Gas Analyzer System/CEMS Introduce

TR-9300, designed by advance online analysis technology and environmental

protection monitor technology, can display dynamic graphic curves and enviro-

nmental protection report through data acquisition and processing system, mon-

itoring the gaseous pollutants (SO2 /NOX /CO/CO2/O2), solid pollutants, temp-

erature, pressure, humidity and flow in flue gas.

Key Feasures

Avoid Downtime:

CEMS, designed for securing safe operation in the Refining, Hydrocarbon Processing and Chemical industries, will help you to avoid downtime by accurately monitoring the required measurements

Avoid Costly Fines:

Our solution could be customized in order to realize a reliable measurement and comply with the local EPA requirements for avoiding the costly fines

Working conditions:

◆ Gas dust content : <500g / Nm3;

◆ Medium temperature : 20 to 650 ℃;

◆ The medium pressure : - 10KPa to + 10Kpa;

◆ Water content : for saturated vapor .

Ambient conditions:

◆ Ambient temperature : 5 to 45 ℃;

◆ Relative humidity : 20 to 85% ;

◆ Atmospheric pressure : 70 to 106kPa;

◆ Sunlight : no direct exposure ;

◆ Air Flow: blowing straight airflow should be < 3m / s.

SPECIFICATIONS 
Component Measuring
Method
Operating Range Zero Shift Span Drift Response Time Linearity Error (F.S.) Output Signal
SO2 IR/UV 0~2000 μmol/mol ±1% FS/7d ±1% FS/7d ≤12 ±1% RS232/RS485 4~20mA
NOX IR/UV 0~2000 μmol/mol ±1% FS/7d ±1% FS/7d ≤12 ±1% RS232/RS485 4~20mA
CO NDIR 0~2000 μmol/mol ±1% FS/7d ±1% FS/7d ≤12 ±1% RS232/RS485 4~20mA
O2 Electrochemistry/Magnetic pressure 0~25% ±1% FS/7d ±1% FS/7d ≤10 ±1% RS232/RS485 4~20mA
PM (Dust) Electrochemistry/Laser 0~2000
mg/m³
±2% FS/7d ±2% FS/8d ≤1 ±1% RS232/RS485 4~20mA
Flow Differential pressure sensing 0~40m/s ±2% FS/7d ±2% FS/8d ≤15 ±2% 40~20mA
Pressure Differential pressure sensing 60~140
kPa
±2% FS/7d ±2% FS/8d ≤15 ±2% 40~20mA
Temperature Thermo-couple 0~500℃ ±2℃/7d ±2℃/7d ≤15 ≤±2℃ 40~20mA
Humidity Capacitance 0~100% RH ±2% FS/7d ±2% FS/7d ≤10 ≤±1.5% 40~20mA

About us

Juneng has been a pioneer in gas analyzers and systems. Juneng solutions, relied upon in research, development and process facilities spanning a wide range of industries including industrial gas processing, hydrocarbon processing, and chemical manufacture, is rapidly developing and considered the professional benchmark for accuracy, reliability and consistency. We can supply Oxygen Gas Analyzer, Hydrogen Gas Analyzer, Flue Gas Analyzer, Dew Point Analyzer, Gas Chromatograph Analyzer and Continuous Emission Monitoring System.

Our experience in gas analysis , established up more than 9 years, coupled with a rich knowledge of its application in the specialty chemicals industry , is your guarantee of safe operation of plant, product quality and process efficiency.

Previous : Underfloor Conditioning Material "Toyo Dry" Next : Absorbing Paper for Air Fresheners Car Vent Air Freshener Paper Hanging Paper Air Freshener
Copyright 2023-2024 - www.globalbiz8.com All Rights Reserved