TR-9300, designed by advance online analysis technology and environmental
protection monitor technology, can display dynamic graphic curves and enviro-
nmental protection report through data acquisition and processing system, mon-
itoring the gaseous pollutants (SO2 /NOX /CO/CO2/O2), solid pollutants, temp-
erature, pressure, humidity and flow in flue gas.
Key Feasures
Avoid Downtime:
CEMS, designed for securing safe operation in the Refining, Hydrocarbon Processing and Chemical industries, will help you to avoid downtime by accurately monitoring the required measurements
Avoid Costly Fines:
Our solution could be customized in order to realize a reliable measurement and comply with the local EPA requirements for avoiding the costly fines
Working conditions:
◆ Gas dust content : <500g / Nm3;
◆ Medium temperature : 20 to 650 ℃;
◆ The medium pressure : - 10KPa to + 10Kpa;
◆ Water content : for saturated vapor .
Ambient conditions:
◆ Ambient temperature : 5 to 45 ℃;
◆ Relative humidity : 20 to 85% ;
◆ Atmospheric pressure : 70 to 106kPa;
◆ Sunlight : no direct exposure ;
◆ Air Flow: blowing straight airflow should be < 3m / s.
SPECIFICATIONS | |||||||
Component | Measuring Method |
Operating Range | Zero Shift | Span Drift | Response Time | Linearity Error (F.S.) | Output Signal |
SO2 | IR/UV | 0~2000 μmol/mol | ±1% FS/7d | ±1% FS/7d | ≤12 | ±1% | RS232/RS485 4~20mA |
NOX | IR/UV | 0~2000 μmol/mol | ±1% FS/7d | ±1% FS/7d | ≤12 | ±1% | RS232/RS485 4~20mA |
CO | NDIR | 0~2000 μmol/mol | ±1% FS/7d | ±1% FS/7d | ≤12 | ±1% | RS232/RS485 4~20mA |
O2 | Electrochemistry/Magnetic pressure | 0~25% | ±1% FS/7d | ±1% FS/7d | ≤10 | ±1% | RS232/RS485 4~20mA |
PM (Dust) | Electrochemistry/Laser | 0~2000 mg/m³ |
±2% FS/7d | ±2% FS/8d | ≤1 | ±1% | RS232/RS485 4~20mA |
Flow | Differential pressure sensing | 0~40m/s | ±2% FS/7d | ±2% FS/8d | ≤15 | ±2% | 40~20mA |
Pressure | Differential pressure sensing | 60~140 kPa |
±2% FS/7d | ±2% FS/8d | ≤15 | ±2% | 40~20mA |
Temperature | Thermo-couple | 0~500℃ | ±2℃/7d | ±2℃/7d | ≤15 | ≤±2℃ | 40~20mA |
Humidity | Capacitance | 0~100% RH | ±2% FS/7d | ±2% FS/7d | ≤10 | ≤±1.5% | 40~20mA |
About us
Juneng has been a pioneer in gas analyzers and systems. Juneng solutions, relied upon in research, development and process facilities spanning a wide range of industries including industrial gas processing, hydrocarbon processing, and chemical manufacture, is rapidly developing and considered the professional benchmark for accuracy, reliability and consistency. We can supply Oxygen Gas Analyzer, Hydrogen Gas Analyzer, Flue Gas Analyzer, Dew Point Analyzer, Gas Chromatograph Analyzer and Continuous Emission Monitoring System.