Home
/
Categories
/
Security & Protection
/
Firefighting Supplies
/
Conventional Fire Alarm Control Panel with Eight Zones
Conventional Fire Alarm Control Panel with Eight Zones
FOB Price 140 USD / Piece
MOQ
1 Piece
Port
shenzhen
Lead Time
5days for sample,10days for bulk order
China
Main Products : smoke detector, heat detector, gas detector, fire alarm control panel, sounder strobe, uv flame detector, reflective beam detector, manual call point, alarm bell
4f, Building B1, Xinhaosheng High-Tech Park, Yonghe Road, Fuyong Town, Baoan District, Shenzhen, Gua Shenzhen, Guangdong
Conventional Fire Alarm Control Panel with Eight Zones Details
Brand Name
zc
Model Number
1008
Place of Origin
China
Supply Type
In-Stock Items
Condition
New
Conventional Fire Alarm Control Panel with Eight Zones Introduce

Skype firealarm87  /wechat 15220176087


Conventional Fire Alarm Control Panel with eight Zones

The PANEL is a 4-zone to 16-zone FACP (Fire Alarm Control Panel), which uses conventional input devices. The panel accepts water flow devices, two-wire smoke detectors, four-wire smoke detectors, pull stations and other normally-open contact devices. Outputs include four Notification Appliance Circuits (NAC, SOUND1-4), three standard Form-A relays (alarm, trouble and supervisory) and an EIA-485 port to interface with remote annunciators and optional remote relay modules. The FACP is field programmable via the panel keypad. It also supervises all wiring, AC voltage and battery level.

This series of panels are basically the same in application and operation, their differences are shown in Table 1-1. PANEL will be described as the example in the following sections.

Table 1-1

FACP

Number of Detection Zones

Number of Sounder Outputs

Output Delay Settings

PANEL-4

4

1

N/A

PANEL-8

8

2

N/A

PANEL-16

16

4

N/A

1.1 ProductFeatures

l 4,8,16 Class B Initiating Device Circuits (IDCs)

โœ“ All zones accept conventional detectors and any normally open contact device

l Four Class B Notification Appliance Circuits (NACs)

l One Form-A Alarm Relay

l One Form-A Trouble Relay

l One Form-A Supervisory Relay

l 3.0 amps of system power

l Max 20 conventional detectors in one zone.

l Auto/Manual mode setting enable walk test.

l Each Zone can be disabled,

l Sound output can be disabled.

l Manual active sound output enabled.

l Able to report short and broken circuit of detection zones.

l Designed with standby batteries and space provision for two sealed lead-acid batteries.

l Testing and disable functions.

l Can connect max 32 repeater panels by RS485 communicaiton port