Features
Safe electron system that do not need traditional key
Both that open method of Password and Key Card
Sensing is fast reception system and RF Card
Alarm and fire sensor that help urgency escape function
Structure of hard Lock device for safety
Convenience and safe use of 16 various melodies
Economical power saving cell design
Water proofing that prepare in use environment
Special number key that protect password
Password alteration(registration)
In Body: Press Registration Button for Password
Press button of the out Body (Input password 2 to 14 digits)
- Confirm success melody & light -
! First registration number is established as "00" (When ship factory)
Register Key Card(Maximum registration number of card is to 30 pieces)
In Body: Press Registration Buttonfor Card Key
Get Card Key in approach 5cm with Card sensor window
Press button of the Out keypad
Within 7 seconds can register continuously if touch other cards within 7 seconds again.
- Confirm success melody & light -
Whole delete of card registration
Press button of In Body
Press button more than 3 seconds
- Confirm success melody & light-
When erase necessary card apart
Press button of In Body
Input Card number of registered order to Keypad (01~30)
Press button more than 3 seconds
Confirm whether card that select erased
- Confirm success melody & light ?
When open door by password
Method1
Open Keypad protection Cover Press Your Password Close Cover
-Confirm success melody & light
Method2
Press button Press Your Password Once more press button
Method3
Open Keypad Cover or Press button
Press any number
Press button
Press your Password
Press button or close Keypad Cover
Want to open by Card Key
1) Press Card button of out body Card Sensor window
Exproxi card makes access
- Confirm success melody & light
Convenient function
Melody establishment |
1) Press Open/Close button for 3 seconds until input tone sounds (IN SIDE) 2) Press 7 button in keypad (OUT SIDE) - Confirm success melody & light |
When cancel melody |
1) After press button for 3 seconds until input tone sounds 2) Is canceled if press 8 button - Confirm success melody & light |
Automatic Locks establishment |
1) Press button for 3 seconds until input tone sounds (IN SIDE) 2) Press 1 button in key pad (OUT SIDE) - Confirm success melody & light |
When cancel Automatic Lock(Personally operation) |
1) Press button for 3 seconds until input tone sounds 2) Press 2 button in key pad - Confirm success melody & light |
Dual Locking - Out Side
Method 1
Setting: Is established if click button more than 3 seconds after lock a door from outside. (Can do outside Dual Lock revocation by registered password and card)
Dual Lock Lever - Interior compulsion
Method 2
Dual Lock lever of interior body in Lock picture position
(This time, with warning sound, all actions do not become)
Warning about outside invasion & Alarm function against Fire
If password and card input mistake happen 5 times, input action stops for 20 seconds
If Lock sensor is bolted compulsorily in the door, alarm rings two times for 7 seconds to 10 seconds interval
Alarm rings if Lock? temperature becomes 70 degrees in fire and the door opens after 10 seconds.
If release warning sound
1) Cancel by Password or Card
2) Separate battery
Caution in Use
When in side battery consumed (When use ten times a day, life of battery is 12 month)
Contact 9V battery to two in put let that is situated on keypad upside and open door by password or card
(If battery is weak during use, that voltage warning sound rings)
This time, password is not removed even if exchange battery.
Cleaning of indoor outside product surface uses soft detergent and soft cloth. (Volatility cleaning material can become surface damage)
If turn indoor body central circle handle to right at any time, door lock opens. (Indoor dual lock lever state confirmation)
Action confirmation does when the door opens after register password and card.
Functions that prepare in urgency situation
1) Fire Sensor
Because fire breaks out, if in door tempera mean temperature gets into 70 degree,
Alarm sound rings and indoor Lock opens after 5~10 seconds.
2) Re Set Button (System return)
When Lock system does not get into normalcy action, press hole? reset button that is situated on keypad's top portion left
Major cause of breakdown
1) When state that entrance does not get closed correctly is continued
2) Because temperature difference is serious room and outside, when there are much moistures
3) Entrance that rainwater falls
4) When turn fast wheel for in body's emergency overly
5) Season door and Frame by change of that is wrenched phenomenon
Installer's caution
There is most of locks breakdown cause in equipment before uneasiness
Ex)
1) When is rubbed because in body? Latch aspect holds up into hasp of door frame
2) When system and each other linked connect cable are wrenched or are pressed down in iron plate to pass.
3) Grasp space of when door gets closed and assemble so that Latch may be able to be acted softly.