Features
Real-time smoke measurement(%, k [m-1]) Portable and LED display Outstanding accuracy, stability and durability Response time of 0.5 second Smoke, SOF measurement Easy to use with handheld terminal(option) Built-in printer(option) RS232C PC program RPM/ Oil temp. meter(option) Auto-Zero/ Span calibration function
Specification
Measuring item
|
Smoke opacity ( %, k [m-1] )
RPM (option), °C (option) |
Principle
|
Light extinction method (Partial-flow sampling type)
|
Light source
|
Green LED(565nm)
|
Detector
|
Photo diode
|
Range
|
0.0~100.0% (0.00~21.42m-1 )
|
Accuracy
|
Less than 1%
|
Warm-up time
|
3~6minutes
|
Display time
|
4 times/sec
|
Power
|
220V / 110V AC 50/60Hz
|
Temperature
|
-10~40℃
|
Dimension
|
450(W) x 200(D) x 245(425)(H) mm
|
Weight
|
About 7kg
|
Option
|
RPM/ Oil temp. meter ,Handheld terminal, Built-in printer , Standard filter, PC program
|
Installation and measurement OP201
Single unit of the analyzer covers the display and the printing of measured value that are recorded in its main body, and can be easily hand-carried. No more than one tester operator behind the wheel would be enough to conduct the free acceleration test to obtain the measured value stepping on the accelerator and using wired or wireless handheld terminal. In supply of diversified basic PC software: PC program are provided in the way to cover regulations from various countries and also ramified for users’ purposes such as governmental agency’s use, inspection or repair of vehicle.