OVERVIEW SECG 5.0 AIO Built-in test circuits as defined in ECG standards Adjustable parameters and selectable options enable to verify DUT with flexibility Provides NST noise simulation - Electrode Motion Artifact / Muscle Noise / Baseline Wander Various signal simulations - Impedance Type Respiration, Wave Modulation Type (Baseline / Amplitude / Frequency) Respiration and lead-off simulation Auto Sequence function assists in conducting semi-automated tests Loads and plays recorded or programmed waveforms Software Development Kit (SDK) allows to develop customized or automated test software with less efforts Optional Standard Assistant software pack simplifies the medical standard with test sequences, options, parameters and pass criteria With Transmittance SpO2 Module (PPG-2TF-660) Simulates ECG and PPG signals to conduct SpO2 and PWTT (Pulse Wave Transit Time) testing Adjustable SpO2 parameters, such as AC, DC, and PI values of R/IR, to confirm the accuracy of DUTs Builds or loads the R curve of the SpO2 function to quickly verify products' performance and assist in comparing against competitors Built-in 14 types of ambient light signals and respiratory variation simulation - add-on signals for more authentic testing Synchronizes ECG and PPG signals while enabling users to adjust the time difference to test the accuracy of non-invasive blood pressure measurement algorithms With Reflectance SpO2 Module (PPG-2R-880/PPG-2R-940) Simulates ECG and PPG signals to conduct SpO2 and PWTT (Pulse Wave Transit Time) testing Adjustable SpO2 parameters, such as AC, DC, and PI values of R/IR, to confirm the accuracy of DUTs Builds or loads the R curve of the SpO2 function to quickly verify products' performance and assist in comparing against competitors Built-in respiratory variation simulation - add-on signals for more authentic testing Synchronizes ECG and PPG signals while enabling users to adjust the time difference to test the accuracy of non-invasive blood pressure measurement algorithms With Reflectance Green Light Heart Rate Module (PPG-1R-525) Outputs green light analog signals to simulate PPG signals Built-in respiratory variation simulation - add-on signals for more authentic testing Synchronizes ECG and PPG signals while enabling users to adjust the time difference to test the accuracy of non-invasive blood pressure measurement algorithms Equipped with RCA to BNC ports to connect to an oscilloscope - outputs amplified and stable signals for viewing the voltage of AC analog signals of green light, optical signals received by the PPG-1R-525, and the switch status of green LED of DUT Testing Scenario