Home
/
Categories
/
Measurement & Analysis Instruments
/
Electronic Measuring Instruments
/
Other Electronic Measuring Instruments
/
ESD Simulator Guns
ESD Simulator Guns
FOB Price 3000 USD / Set
MOQ
1 Set
China
Main Products : Goniophotometer, LED Test Instruments, Electrical Safety Testing, Environmental Test Chamber
113-114, No.1 Building, Nanxiang Zhidi Industry Park, No. 1101, Huyi Road Shanghai, Shanghai
ESD Simulator Guns Details
Brand Name
LISUN
Model Number
ESD61000-2
Place of Origin
China
Supply Type
OEM Service
Condition
New
ESD Simulator Guns Introduce

ESD simulator guns (Electrostatic Discharge Generator/Electrostatic Gun/ESD Guns) is in full compliance with IEC 61000-4-2, EN61000-4-2, ISO10605, GB/T17626.2, GB/T17215.301 and GB/T17215.322.

What is a ESD test?

The static electricity generated by the human body to the object or between two objects may cause the electrical and electronic equipment circuits to malfunction or even be damaged. The ESD generator is designed for the withstanding ESD performance measurement for the assessment of electrical and electronic equipment. ESD61000-2/ESD61000-2A has a LCD touch screen in both English and Chinese.

What is an esd simulator gun used for?

Electrostatic discharge simulator is highest electrostatic voltage can be up to 30 kv, which is enough to cover the most severe standard grade of electrostatic voltage requirement (the voltage requirements of the grade 4 air discharge electrostatic is 15 KV). The ESD test gun can be used for the most of electrical and electronic equipment for electrostatic discharge test, and also can ensure comparability and reproducibility of test.

Specifications:

Product ModelESD61000-2ESD61000-2A
Output Voltage0.1~20kV±5%0.1~30kV±5%
PolarityPositive/NegativePositive/Negative
Energy Storage Capacitance150pF±10% (Replaceable)150pF±10% (Replaceable)
Discharge Resistor330Ω±5% (Replaceable)330Ω±5% (Replaceable)
Current Rise Time0.6~1ns0.6~1ns
Testing FunctionsSingle, Count, 20pps, Air, Contact, IEC levelSingle, Count, 20pps, Air, Contact, IEC level
Trigger ModeMANUAL/AUTOMANUAL/AUTO
Number of Discharge1~99991~9999
Repetition0.05s~99.99s0.05s~99.99s
Working PowerAC220V (Option 110V) ±10%, 50/60HzAC220V (Option 110V) ±10%, 50/60Hz

Calibrate Report:

Output Voltage (kV)First Peak Current (A)Current at 30ns (A)Current at 60ns (A)Rise Time (ns)
27.294.102.200.93
415.407.904.300.97
623.2012.106.500.97
829.4016.209.300.89
-27.393.502.300.92
-415.507.704.300.89
-623.4011.906.300.90
-831.80