Features Continuous DC operation or capacitor charging application. Output voltage: 1KV/2KV/5KV/10KV/20KV/30KV/40KV/50KV/60KV optional. Output power: 5KW/10KW/15KW Output voltage & current both 0 ~ 100% rated value continuously adjustable. CV & CC working modes Max. charging/discharging repetition frequency: 50kHz Charging/discharging repetition accuracy: <2% (@50Hz) Forced air cooling, very rugged design Remote control (analog signal or RS port) (optional) Principle description
The HP unit is made up of four different functional parts as shown below:
Rectifier Part
This stage takes three-phase 380Vac or 440Vac input, then after rectifies and filters, it creates a 600Vdc pulsing DC output.
High Frequency DC/AC Part
This stage uses an IGBT (Insulated Gate Bipolar Transistor) full bridge circuit to convert the pulsing DC to a high frequency AC waveform that feeds the next stage.
Series Resonant Tank Part
This part is an inductor in series with a capacitor. This LC network defines the characteristic impedance of the system and the frequency at which the AC current resonant.
High Voltage AC/DC Part
This part uses a transformer to step up the high frequency AC the necessary high voltage level. A rectifier circuit is then used to convert the high voltage, high frequency AC to the high voltage DC
Theory of Operation
The IGBT full bridge inverter and the Series Resonant Tank circuit are the key components in this power supply.
The series resonant inverter converts input voltage source to a equivalent current source, each pulsing is equivalent to an energy pack, which is sent to output load or output filtering capacitor after HV rectifying.
Different output voltage and current corresponds to different output pulsing frequency, adjusting pulsing frequency leads to output voltage and current changes.
Technical Specification:
Input Voltage: 380--440Vac Output Power: 5~20KW Output Voltage: 10KV/20KV/30KV/40KV/50KV/60KV (for other output voltage, please contact us), adjustable output voltage. Line regulation: 0.1% Load regulation: 0.1% Power factor: ≥0.9 Total Efficiency: ≥0.92 Output polarity: as per clients’ requirements. Cooling: Forced air cooling Dimension: as per output required. Operation Temperature: -10℃ to 40℃ Humidity: <90% Weight: as per output required.
Remark: Repetition accuracy depends on load capacity and charging/discharging frequency, accuracy range: 0.1% ~ 2% In case of special requirements, HV isolation switch should be installed between output and capacitors to prevent damages caused by capacitor discharging reverse peak voltage.
Custom-made requirements acceptable