Items | Technical Para. |
Peak open circuit voltage | 0.25~7.0kV±10% |
Voltage open circuit wave | leading 0.5us±20%, voltage short circuit wave≤1us |
Voltage rising time(the first peak) | 0.5us(±30%) |
Current rising time(the first peak) | ≤1us |
Oscillation frequency | 100kHz±10% |
Pulse interval | 1s~99999s |
Pulse number | 1~99999 |
Output impedance | 12Ω、30Ω |
Polarity | positive、negative positive and negative alternative |
Trigger phase | asynchronous/phase synchronization/external synchronization,1°step by step particular phase switching(0°~90°~180°~270°) |
Trigger mode | manual/automatic/external trigger |
Voltage attenuation | 0.4<Pk2/Pk1<1.1,0.4<Pk3/Pk2<0.8,0.4<Pk4/Pk3<0.8 |
Embedded single/three-phase coupling decoupling network indication
| 3P5W, line voltage 450VAC/20A, DC220VDC/20A |
Communication | RJ45、USB |
Position | single phase 1position, three-phase 1position(standard) |
Power supply | AC220V±10%,50Hz ,(AC120V/240V optional) Max.consumption:1000VA |
Dimension | cabinet:(600×800×1920)×2 |