Home
/
Categories
/
Electrical Equipment & Supplies
/
Other Electrical Equipment
/
HVLP High Voltage Linear DC Power Supply
HVLP High Voltage Linear DC Power Supply
FOB Price
Port
Shanghai
Lead Time
30~45 days after order confirm and advance payment received
China
Main Products : dc power supply, ac power supply, inverter, test power supply
#343, No. 8 Wenchang Middle Road Yangzhou, Jiangsu
HVLP High Voltage Linear DC Power Supply Details
Brand Name
Idealtek
Model Number
HVLP
Place of Origin
China
HVLP High Voltage Linear DC Power Supply Introduce

Introduction

HVLP series is high voltage linear DC power supply uses power frequency transformer AC/DC conversion technology, series voltage-rise circuit design and matured filtering circuit to ensure controllable and stable HV DC output.

As it uses power frequency transformer, it is more reliable and durable than switching mode power supply that using high frequency PWM technology and it does not have high frequency radiation interference like switching mode power supply has.

Its matured and perfect filtering circuit gives it super low ripple and very good output precision, also it has complete protection functions

As features above, this series is mostly used for HV capacitor charging, HIPOT test and other kinds of HV tests.

Features: Over 200 models, output voltage: 800V ~ 50KV, output current: 0 ~ 500A, output power: 0KW-400kW Constant voltage mode and constant current mode, automatic switchable, output voltage / current continuously adjustable from 5% to 100% rated value. Over voltage protection: Over voltage value continuously adjustable from 0 to 110% rated value, auto-shut down when output voltage exceeds the over voltage set point Short protection: Withstand short-circuit under start-up or any working modes, sound & light alarm when output has short. (<6KV) Auto-tripping when short-circuit and sound & light alarm (>6KV) Over load protection: Auto-tripping when power supply or load has fault and output current exceeds 1.5 times of rated value. Short alarm: sound & light alarm when output short-circuit. (optional) Automatic off-load and discharging: when power supply shutdown, power supply will automatically cut off load and discharge electric in load for safety. (optional) Output display: Voltage & current both LED digital display (standard), LCD display (optional) or LCD touch screen display (optional) Pulsing working: could add time controller to be pulsing power supply (optional) Communication port: RS232/RS485 for connection with computer to be remote controlled & monitored by computers (optional) Analog signal: 0 ~ 5V (10V) or 4 ~ 20mA analog signal for output voltage & current control (optional)

Application Institutes, university HV tests HV electronics component burn-in test, gas discharging test Klystron, magnet tube, electronic gun driving. HV capacitor charging Other conditions need HV output.

Technical Specification:

Electrical Characteristics
  1. Input,Output
Input: Single-phase 220Vac±10% 50Hz±10% (≤10KW)
Three-phase 380Vac±10% 50Hz±10% (>10KW)
Output:DC C.C. and/or C.V.
Max output: As requirements
(Grounding: two optional modes, default configuration is negative high-voltage, positive grounding)
 1. Positive high-vltage, negative grounding
 2. Negative high-voltage, positive grounding
  1. Accuracy (C.V.)
Line regulation: ≤0.1% Of the rated value (output voltage change ratio under input ±10% change)
Stability: during 8 hrs≤0.3% of the rated value (output voltage change ratio due to 8 hours continuously working)
Temp. coeff.offset: ≤0.04% of the rated value/℃(output voltage change ratio due to environment temperature changes)
Load regulation(load 0~100%): ≤0.3% of the rated value (output voltage change ratio due to output current change from 0 to rated value)
  1. Accuracy (C.C.)
Line regulation: ≤0.1% Of the rated value (output current change ratio under input ±10% change)
Stability: during 8 hrs≤0.3% of the rated value(output current change ratio due to 8 hours continuously working)
Temp. coeff.offset: ≤0.04% of the rated value/℃(output current change ratio due to environment temperature changes)
Load regulation(load 0~100%): ≤0.3% of the rated value (output current change ratio due to output voltage change from 0 to rated value)
  1. Ripple +noise(r.m.s)
Positive high-voltage, negative grounding: ≤0.2% of the rated value+10mV (80%~100% rated output)
Negative high-voltage, positive grounding: ≤0.1% of the rated value+10mV (80%~100% rated output)
  1. Programming output voltage
Adjustable (5%~rated value) or CV
  1. Programming output current
Adjustable (0~rated value) or CC
  1. Adjusting mode
10-turn Potentiometer
Key button (optional)
  1. Protections function
Auto-protection when over voltage/over current/lack phase
  1. Short protection
Withstand short-circuit and alarm (<6KV)
Auto-tripping when short-circuit (≥6KV)
  1. Working mode
Withstand long-term continual working at full load
  1. Read output
Digital LED
  1. Display precision
As per output values
  1. Display accuracy
≤±1%±1digit (range:5%~50% of the rated value)
≤±0.5%±1digit (range:50%~100% of the rated value)
  1. Load characteristic
On demand
  1. Operating condition
Location: indoor use only
Temperature:-20°C ~ +40°C
Humidity:≤80%
  1. Spare parts
Company standard (fuse * 1pc, high-voltage output line * 1pc, operation manual * 1pc)

● Input Voltage: Power source voltage can be changed to others on request. ● Custom-made specifications are on request.

Previous : Mechanical Thermal Imaging Optical Shutter Next : LS9955/56 Automatic Safety Test System
Copyright 2023-2024 - www.globalbiz8.com All Rights Reserved