Product Description
Portable Syngas Analyzer for CO2 Heating Value biomass gasifications steel making process applications
Here are a few considerations and recommendations for portable syngas analyzers for CO2 heating value measurement in biomass gasification for steelmaking processes:
1. Gas Components Monitoring: Ensure the analyzer can accurately measure the components of syngas, including CO, CO2, H2, CH4, and other trace gases that might be present.
2. Accuracy and Precision: Look for analyzers with high accuracy and precision in measurements. This is crucial for reliable data in process optimization.
3. Response Time: A fast response time is important for real-time monitoring and control. It helps in making quick adjustments to the process.
4. Temperature and Pressure Range: Ensure the analyzer can operate within the range of temperatures and pressures typically encountered in the gasification process.
5. Durability and Portability: Since it's a portable analyzer, it should be robust enough to withstand the conditions of an industrial setting. It should also be easy to transport and set up.
6. Calibration and Maintenance: Check if the analyzer has a straightforward calibration process and inquire about maintenance requirements.
7. Data Logging and Communication**: Look for features like data logging, which can be useful for trend analysis. Also, consider if it has the capability to communicate data to a central monitoring system.
8. Safety Features: Ensure the analyzer has safety features in place, especially when dealing with potentially hazardous gases.
9. Power Source: Consider the power requirements and if the analyzer can be powered using readily available sources in your facility.
10. Cost and Support: Evaluate the cost of the analyzer and the availability of technical support from the manufacturer.
For specific product recommendations, I recommend consulting with specialized suppliers or reaching out to companies that specialize in gas analysis equipment. They can provide you with detailed information on available models that meet your specific requirements. Keep in mind that the market might have new offerings beyond my last training data in September 2021, so it's a good idea to check for the latest options.
O2%+CO%+CO2%+CH4%+CnHm%+H2% All measurement in one unit
Applications
coal chemical processsteel making process as blast furnace, converter, coking, direct ironore smelting reductionsyngas production from Biomass and coal gas gasification processes
Components | Method | Range | Resolution | Precision |
CO2 | NDIR | 0-5% to 100% | 0.01% | ≤2% |
CO | NDIR | 0-5% to 100% | 0.01% | ≤2% |
H2 | TCD | 0-5% to 100% | 0.01% | ≤3% |
O2 | ECD | 0-5% to 25% | 0.01% | ≤3% |
CH4 | NDIR | 0-5% to 100% | 0.01% | ≤2% |
CnHm (optional) | NDIR | 0-5% to 10% | 0.01% | ≤2% |
Note: Measurement range can be customized by the requirement. Max: 6 components at the same time. | ||||
Response Time (TD+T90) | <10s (NDIR) | |||
Response Time | 15min | |||
I/O port | RS232 | |||
Work temperature | 0~50℃ | |||
Relative humidity | 5~85% | |||
Ambient air pressure | 86~108kPa | |||
Power supply | AC 220±10%V 50Hz±1Hz | |||
Weight | About 3.5kg |