Product Details
No | Item | Condition | Specification |
1 | work Voltage | work Voltage B+ to B- | 26.4~+45V(12S LFP cells) |
2 | Suggest working conditions | max continuous discharge current | 50A |
3 | max continuous charge current | 20A | |
4 | suggest working temperature | -20℃~+60℃ | |
5 | Cells Overcharge | Detection voltage/1CELL | 3.75±0.05V |
6 | Release voltage/1CELL | 3.6±0.05V | |
7 | Detection delay time | 0.8~1.2S | |
8 | Cells Over discharge | Detection voltage/1CELL | 2.2±0.1V |
9 | Release voltage/1CELL | 2.35±0.1V | |
10 | Detection delay time | 100.00ms | |
11 | Over discharge current | Over current | 120A |
14 | delay time | 400~1200.00ms | |
15 | Short detection | Short detection delay time | 150~350us |
16 | Release Conditions | Cut off load | |
17 | Normal current consumption | Normal current consumption of PCM | Max 80.00uA |
18 | 0V charger | allowed 0V change | YES |
19 | Balanced current | 35-55mA |