Application of Melting furnace
Intermediate Frequency Electrical Melting Furnace, also called as Induction Smelting Furnace or medium frequency induction melting furnace, which converting three phase power current into single phase intermediate frequency current and enabling metal to produce eddy current loss through electromagnetic field induction to achieve heating and melting. It is applicable to melting, heating or insulting of steel, copper, iron, aluminum, zinc, tin, nickel silver and other ferrous, nonferrous metal. It can also be used for other heating treatment before forging, sintering and tube-bending forming in the casting and melting industries.
Intermediate Frequency Electrical Furnace Performances and Features
1. Adopt a zero-voltage scanning soft-start mode, it can be started or stopped in any case and at any time, so it has no impact on power supply.
2. Fast smelting with low production cost; Low-pollution and environment-friendly;
3. Start melting from cold furnace. Solution can be fully empty. Change molten material easily.
4. Power adjustment is flexible. Be able to adjust continuously and smoothly. Temperature is even and can be easily controlled. Less oxidation burning. Metal components is even.
5. Furnace shell is adopt aluminum alloy or steel structure, covering small area; Convenience to overturn the furnace, according to your need to adpot overturing way like electric, manual, hydraulic.
6. It can automatically adjust to match the load impedance, The equipment will always run in good working condition without adjustment of compensation capacitance, low fault rate; Power supply system has diagnostic error function that make it easy to check and maintenance.
7. Suitable for intermittent production.
IF Melting Furnace constitution
1. Furnace body
2. Medium frequency power supply
3. Water cooling cable
4. Reduction machine
5. Crucible mold
6. Compensation capacitor rack.
Furnace Capacity | Rating Power | Input Voltage | Input Phase | Input Current | Assorted Transformer | Output Voltage | Output Frequency | Melting Time | Volume | Weight |
GW-0.05T | 50KW | 380V | 3 | 80A | 60KVA | 750V | 2.5KHZ | 20-60Min | 1.2 m³ | 350KG |
GW-0.1T | 100KW | 380V | 3 | 160A | 120KVA | 750V | 1KHZ | 20-60Min | 6 m³ | 1500KG |
GW-0.15T | 100KW | 380V | 3 | 160A | 120KVA | 750V | 1KHZ | 30-70Min | 6.5m³ | 1600KG |
GW-0.2T | 120KW | 380V | 3 | 192A | 150KVA | 750V | 1KHZ | 30-70Min | 7.5m³ | 1700KG |
GW-0.3T | 130KW | 380V | 3 | 208A | 150KVA | 750V | 1KHZ | 30-70Min | 8.5m³ | 1800KG |
GW-0.4T | 250KW | 380V | 3 | 400A | 315KVA | 750V | 1KHZ | 30-70Min | 9.5m³ | 2300KG |
GW-0.6T | 350KW | 380V | 3 | 560A | 400KVA | 750V | 1KHZ | 40-80Min | 11m³ | 2500KG |
GW-0.75T | 450KW | 380V | 3 | 720A | 500KVA | 750V | 1KHZ | 40-80Min | 12m³ | 3800KG |
GW-1T | 600KW | 380V 380V-2 | 3/6 | 960A 480A | 600KVA 800KVA | 750V 1300V | 0.8KHZ | 50-90Min | 13m³ | 4500KG |
GW-1.25T | 800KW | 380V 380V-2 | 3/6 | 1280A 640A | 800KVA 1250KVA | 750V 1300V | 0.8KHZ | 50-90Min | 14m³ | 5000KG |
GW-1.5T | 1000KW | 380V 380V-2 | 3/6 | 1600A 800A | 1250KVA 1500KVA | 750V 1300V | 0.8KHZ | 50-90Min | 15m³ | 5500KG |
GW-2T | 1250KW | 660V 380V-2 | 3/6 | 1120A 1000A | 1500KVA 1800KVA | 1300V | 1300V | 50-90Min | 17m³ | 6000KG |
GW-3T | 1500KW | 660V 380V-2 | 3/6 | 1350A 1200A | 1800KVA 2000KVA | 1300V | 1300V | 60-100Min | 20m³ | 7000KG |
GW-5T | 2500KW | 1000V 660V-2 | 3/6 | 2000A 1120A | 3000KVA 3500KVA | 1300V | 1300V | 60-100Min | 23m³ | 8500KG |