NCS-FI105 Fieldbus (Profibus) To 4-20mA Current / Digital Signal To Analog Converter
NCS-FI105 Fieldbus (Profibus) To 4-20mA Current / Digital Signal To Analog Converter
FOB Price
China
Main Products : Control System, Communication Controller, Communication Chips, Transmitter
17-8 Wensu, Hunnan District, Shenyang, Liaoning,China Shenyang, Liaoning
NCS-FI105 Fieldbus (Profibus) To 4-20mA Current / Digital Signal To Analog Converter Details
Brand Name
Microcyber
Place of Origin
China
Accuracy
0.05%
Protocols
FF, PA
Explosion-proof
Intrisic safe
Model Number
NCS-FI105
NCS-FI105 Fieldbus (Profibus) To 4-20mA Current / Digital Signal To Analog Converter Introduce

Product Overview

NCS-FI105 fieldbus to current Converter is used to convert fieldbus signals to conventional analog signals. It can receive fieldbus signals, and convert them to 4-channel 4~20mA analog signals. NCS-FI105 is the converter between fieldbus system and control valve/other actuator.

NCS-FI105 is an intelligent instrument and complies with FF Fieldbus Specification. It can be interlinked with several FF equipment. Abundant function blocks are integrated into NCS-FI105, and so it can complete not only the general measuring but also the complex controlling strategy. According to the requirement and actual application environment, the users can choose different function blocks to implement different function.

NCS-FI105 utilizes digital technology, which simplifies the interface between the control center and the field equipment. And so the expense of installing, running and maintenance can be reduced.

Features

Numver of channels:4 Output of signal:4~20mA Bus signal:31.25kbit/s Power:9~32VDC Current consumption(static):≤14mASpecification

Parameters

Parameter

Value

Input signal

4~20mA

Channels

4 Channels

Current output 

NPN collector output

Power supply

9 ~ 32 VDC ;Current Dissipation (static): ≤ 14mA

Fieldbus Signal

Communication Baudrate 31.25kbit/s, current-mode

Insulation

Between housing and terminal board:

500 Vrms (707 VDC)

Display

6 bits digital number and 5 bits characters LCD display (Optional)

Temperature range

- 40 ~ 85℃ (No display)

- 30 ~ 70℃ (display)

Humidity Range

0% ~ 100% RH

Start Time

≤ 5s

Protection grade

IP 65

EMC

Designed to comply IEC 61000

Size

Size of NCS-FI105 Fieldbus/Current Converter (Unit:mm)