No Break UPS with Wide input voltage and Copper Isolation transformer
1.Low Frequency Online UPS is 10k-100k
2.No Break UPS for south America
3.three phase Low Frequency Online UPS with high quality
4.No Break UPS with Wide input voltage
Key Features
1: Humanized display interface
2: DSP technology guarantees high reliability
3: True online double conversion, equipped with IGBT and output transformer
4: Charging/rectifier/inverter fully digital control technology
5: Intelligent battery management to prolong battery lifecycle
6: Redundant fan design and independent ventilation enhance durable operation under harsh environment
7: Intelligent control of multiple CPU
8: Accept dual-mains input
9: Parallel operation with up to 4 units (option)
10: Variety of communication options available
11: Good after-sale services
Technical Specification
LS33 Series 10K - 80Kva |
||||||||
MODEL | 10K | 20K | 30K | 40K | 60K | 80K | ||
CAPACITY | 10KVA/8KW | 20KVA/16KW | 30KVA/24KW | 40KVA/32KW | 60KVA/48KW | 80KVA/64KW | ||
INPUT | ||||||||
Nominal Voltage | 3 x 380VAC/400VAC (3Ph + N) | |||||||
Acceptable Voltage Range | 305VAC ~ 460VAC | |||||||
Frequency | 46-54Hz or 56-64Hz | |||||||
INVERTER | ||||||||
Nominal Voltage | 3 x 380VAC/400VAC (3Ph + N) | |||||||
Precision | Stationary: ±1% Transitory: ±5% (load variations 100-0-100%) |
|||||||
Frequency | 50/60 Hz synchronised ±1 % With mains absent ±0.1 Hz |
|||||||
Max. Synchronisation Speed | ±1 Hz/s | |||||||
Waveform | Pure Sinewave | |||||||
Total Harmonic Distortion (THDv) | <2% (Linear Load) <5% (Non-linear Load) |
|||||||
Phase Displacement | 120º ±1% (balanced load) 120º ±2% (imbalances 50% of the load) |
|||||||
Dynamic Recovery Time | 1 cycle at 98 % of the static value | |||||||
Admissible Overload | 110% for 10min; 150% for 60sec ; >160% for 200ms | |||||||
Admissible Crest Factor | 3:1 | |||||||
Admissible Power Factor | 0.6~1 (inductive or capacitive) | |||||||
Imbalance Output Voltage @ 100% Unbalanced Load | <1% | |||||||
Current Limit | High overload, short-circuit: RMS Voltage Limit High Crest-Factor current: Peak Voltage Limit |
|||||||
STATIC BYPASS | ||||||||
Type | Solid state | |||||||
Voltage | 3 x 380VAC/400VAC (3Ph + N) | |||||||
Frequency | 50/60 Hz | |||||||
Activation Criterion | Microprocessor control | |||||||
Transfer Time | Zero | |||||||
Admissible Overload | 150% for 1 hour; 180% for 30sec; >200% for 200ms | |||||||
Transfer to Bypass | Immediate, for overloads above 160% | |||||||
Retransfer | Automatic after alarm clear | |||||||
MAINTENANCE BYPASS | ||||||||
Type | Without interruption | |||||||
Voltage | 3 x 400V (3Ph + N) | |||||||
Frequency | 50/60 Hz | |||||||
Overall Efficiency | Line Mode | 90% | 91% | 92% | 93% | |||
Battery Mode | 90% | 91% | 93% | 93% | ||||
BATTERY & CHARGER | ||||||||
Battery Type and Numbers | 12VDC x 16 pcs | 12VDC x 32 pcs (29~32 pcs adjustable) | ||||||
Nominal Battery Voltage | 192 VDC | 384 VDC (Based on 32pcs batteries) | ||||||
Charging Method | CC/CV | |||||||
Precision | ±1% | |||||||
Charging Current | Max.: 40 A | |||||||
Charging Voltage | 216 VDC | 432 VDC (Based on 32pcs batteries) | ||||||
PHYSICAL | ||||||||
Dimensions, D x W x H(mm) | 656 x 405 x 817 | 656 x 405 x 941 | 840 x 432 x 1140 | 975 x 554 x 1286 | ||||
Net Weight (Kgs) | 180 | 205 | 295 | 330 | 451 | 519 | ||
* Product specifications are subject to change without further notice |