OEM 1500 watt Off Grid pure sine wave inverter 12v 220v with bypass function
It is an easy way to provide access to electricity when camping or for emergency use during a power outage.In addition,it has two USB-2 chargers for phones, tablets, etc.it’s an asset when power is off for an extended period (such as with hurricanes), you have an immediate place to go for charging phones and medical issues such as nebulizer treatments.
【SAFE FOR USE】 LED indicators for under-voltage and over-voltage protection, over-temperature protection, over-load protection, and short circuit indication. Cooling funs and ground-fault circuit interrupter (GFCI) protection.
【PROTECTS YOUR ELECTRONICS】 Advanced pure sine wave technology provides quality AC equivalent to grid power which will protect and extend the life of your electronics and appliances. With its quiet and high inductive loads, there are no strange buzzing sounds when your electronics are turned on and allow them to run smoother, cooler, and quieter.
【EASY TO USE】 Offers a built-in 5V/2.1A USB port, 3 AC Outlets and 1 AC Terminal Block, along with a 19.8ft Wired Remote Control.
【RELIABLE QUALITY】 ETL certified product ensures safety and quality. Offers 1-Year material and workmanship warranty.
pure sine wave inverter specifications:
MODEL | TFS1500-112 | TFS1500-124 | TFS1500-148 | TFS1500-212 | TFS1500-224 | TFS1500-248 | |
Output | AC Voltage | 100/110/120VAC | 220/230/240VAC | ||||
Rated Power | 1500W | ||||||
Surge Power | Load 120~150%(3min.);3000W(3sec; resistive) | ||||||
Waveform | Pure Sine Wave(THD<3%) | ||||||
Frequency | 50/60Hz ±0.05% | ||||||
AC Regulation | ±5% | ±10% | |||||
Power Factor Allowed | COSθ-90°~COSθ+90° | ||||||
Standard Receptacles | USA/British/Franch/Schuko /UK/Australia/Universal etc. optional | ||||||
LED Indicator | Green for power on, red for faulty status | ||||||
USB port | 5V 2.1A | 5V 2.1A | ------ | 5V 2.1A | 5V 2.1A | ------ | |
LCD display | voltage, power, protection status ( optional) | ||||||
Remote control function | default | ||||||
Remote controller | CR80/CRD80 optional | ||||||
Input | No Load Current Draw | ≤1.1A | ≤0.80A | ≤0.70A | ≤1.1A | ≤0.80A | ≤0.70A |
DC Voltage | 12VDC | 24VDC | 48VDC | 12VDC | 24VDC | 48VDC | |
Voltage Range | 10.5~15VDC | 21~30VDC | 42~60VDC | 10.5~15VDC | 21~30VDC | 42~60VDC | |
Efficiency(Typ.) | 89%~93% | ||||||
Fuse | 40A×6 | 20A×6 | 10A×6 | 40A×6 | 20A×6 | 10A×6 | |
Remote Control | Function (optional) | ||||||
Protection | BAT. Low Alarm | 10.5±0.5VDC | 21±1.0VDC | 42±2.0VDC | 10.5±0.5VDC | 21±1.0VDC | 42±2.0VDC |
BAT. Low Shutdown | 10±0.5VDC | 20±1.0VDC | 40±2.0VDC | 10±0.5VDC | 20±1.0VDC | 40±2.0VDC | |
Over Load | Shut down output voltage , restart to recover | ||||||
Over Voltage | 15.5±0.5VDC | 31±1.0VDC | 62±2.0VDC | 15.5±0.5VDC | 31±1.0VDC | 62±2.0VDC | |
Over Temperature | Shut down output voltage , recover automatically after temperature goes down | ||||||
Output Short | Shut down output voltage , restart to recover | ||||||
DC Input Reverse Polarity | By fuse | ||||||
Earth Fault | Shut off o/p when the load has electrical leakage | ||||||
Soft Start | Yes, 3-5 Seconds | ||||||
Environment | Working Temp. | 0~+50℃ | |||||
Working Humidity | 20~90%RH non-condensing | ||||||
Storage Temp.&Humidity | -30~+70℃,10~95%RH | ||||||
Safety & EMC | Safety Standards | Certified UL 458(only for "GFCI" receptacles) | Certified EN 60950-1; 2006+A11: 2009+A1: 2010+A12: 2011+A2: 2013. | ||||
Isolation Resistance | I/P-O/P:100M Ohms/500VDC | ||||||
EMI Conduction & Radiation | Certified FCC class A | Certified EN 62040-2:2006,EN61000-3-2; EN61000-3-3; | |||||
EMS Immunity | ------ | Certified IEC61000-4-3, IEC61000-4-6 | |||||
E-MARK | ------ | Certified ECE RIO.05:2014 | |||||
Others | Dimension(L×W×H) | 325.2×281.3×112.7mm | |||||
Packing | 5.2kg;2pcs/11.1kg/0.053m³ | ||||||
Cooling | Load control fan or by thermal control fan | ||||||