TheMF010 SeriesLow Temperature Oxygen Sensors is designed to determine the oxygen concentration in air or inert gas mixtures with temperatures of-100 °C to 250 °C [-148 °F to 482°F]max.
The MF020SeriesHighTemperatureOxygen Sensors is designed to determine the oxygen concentration in air or inert gas mixtures with temperatures of-100°C to400°C [-148°Fto752°F]max.
These products are particularly suitable for measuring oxygen in areas that are not easily accessible, or inclosed systems, such as ventilation pipesand containers. The MF010and MF020 Series may both be supplied with a measuring range of
1vol%O to 25vol%Oand0.1vol%Oto100vol%O.The
Sensorelectronicsinclude:
1. Signal amplifier
2. Controlfor theionic pumpwithan analogcomponent
3. Testcomponent
4. Internalmonitoringlogiccomponent
5. Power supply forthesensor heating elementandthe analoganddigitalcomponents
6. Reset
7. Voltagemonitor
8. Analog output
9. Bi-directional digitaloutput
10. Internalpotentiometer
The sensor outputs the measured values via ananalog
FEATURES
Nomoving parts Low powerconsumption No needfortemperaturestabilization Functionaltestingandcalibration inambientair Longlife
POTENTIAL APPLICATIONS
Furnace/heatingboilercontrol Industrial processcontrol Combustionsystems Compostsystems Environmentalcontrol
MF010 SeriesandMF020Series
TABLE 1. MF010 SERIESSPECIFICATIONS AND ORDERINFORMATION
Characteristic |
CatalogListing |
|||
MF010-0-LC1 MF010-1-LC1 MF010-2-LC1 |
MF010-0-LC2 MF010-1-LC2 MF010-2-LC2 |
MF010-0-LC3 MF010-1-LC3 MF010-2-LC3 |
MF010-0-LC4 MF010-1-LC4 MF010-2-LC4 |
|
Temperature rangeat probetip |
-100 °C to 250 °C [-148 °Fto482 °F] |
|||
Output |
0 Vdcto10 Vdc |
4mA to 20mA |
||
O2 range(O2partialpressure) with equivalentO2 output |
1mbar to250mbar 0.1 vol%O2to 25 vol%O2 |
1mbar to1000mbar 0.1 vol%O2to 100 vol%O2 |
1mbar to250mbar 0.1 vol%O2to 25 vol%O2 |
1mbar to1000mbar 0.1 vol%O2to 100 vol%O2 |
Probelength: -0-LXX -1-LXX -2-LXX |
220mm[8.7in] 400mm[15.7in] 600mm[23.6in] |
TABLE 2. MF020 SERIESSPECIFICATIONS AND ORDERINFORMATION
Characteristic |
CatalogListing |
|||
MF020-0-LC1 MF020-1-LC1 MF020-2-LC1 |
MF020-0-LC2 MF020-1-LC2 MF020-2-LC2 |
MF020-0-LC3 MF020-1-LC3 MF020-2-LC3 |
MF020-0-LC4 MF020-1-LC4 MF020-2-LC4 |
|
Temperature rangeat probetip |
-100 °C to 400 °C [-148 °Fto752 °F] |
|||
Output |
0 Vdcto10 Vdc |
4mA to 20mA |
||
O2 range(O2partialpressure) with equivalentO2 output |
1mbar to250mbar 0.1 vol%O2to25vol%O2 |
1mbar to1000mbar 0.1 vol%O2to100vol%O2 |
1mbar to250mbar 0.1 vol%O2to25vol%O2 |
1mbar to1000mbar 0.1 vol%O2to100vol%O2 |
Probelength: -0-LXX -1-LXX -2-LXX |
220mm[8.7in] 400mm[15.7in] 600mm[23.6in] |
TABLE 3. MF010 AND MF020 SERIES GENERAL SPECIFICATIONS
Characteristic |
Parameter |
Supplyvoltage |
24 Vdc ±5% |
Supplycurrent |
500mA |
Ambient temperature (includessolar radiation |
-10°C to50°C [14 °Fto122°F] |
Resolution |
12 bit |
Heat-uptime |
approx.10min |
Accuracy |
±2%FS (FullScale) |
Reproducibility |
±1%FS (FullScale) |
Gas flowrate |
0m/s to10m/s |
Reactiontime |
approx.3s |
Incidentalpermissibleacceleration |
30g |
Repetitive permissibleacceleration |
5g |
Bar probematerial |
stainlesssteel1.4301 |
Housingmaterial |
Makrolon 8030 (30%GV),UL94 V-1 |
Housingsealing |
IP65 |
Connectorsealing |
IP67 |
Weight (withoutbar probe) |
150g[5.3oz] |
Termination (femaleconnector) |
99-4226-14-07 (Binder693 series) |
Certification |
complieswith EMC directivesEN 50082-2and EN 50081-1anddirectives 89/336/EWG and 92/31/EWG |