Patient Monitor Details
Model Number
ORC-9000
Place of Origin
China
Patient Monitor Introduce

*12.1" color TFT screen

*Multi‐channel display

*Big font interface

*ST and arrhythmia analysis

*Drug dose calculation and titration table

*OxyCRG dynamic view display

*Respiration monitoring with apnea alarms,Alarm review, arrhythmia review

*Patient info. Input

*Anti‐defibrillation design

*NIBP over pressure protection

*Plug‐in rechargeable battery, AC/DC available.

*Supporting wire or wireless network.

Technical Specifications

ECG

Lead Mode 5 Leads (R, L, F, N, C or RA, LA, LL, RL,V)

Lead selection I, II, III, avR, avL, avF, V

Wavef orm 2 ch

Lead mode 3 Leads ( R, L, F or RA, LA, LL)

Lead selection I, II, III,

Wave form 1 ch

Gain 2.5mm/mV, 5.0mm/mV, 10mm/mV,20mm/mV, auto

HR and Alarm Range Adult 15 ~ 300 bpm

Neo/Ped 15 ~ 350 bpm

Accuracy ±1% or±1bpm, which is greater

Resolution 1 bpm

Sensitivity > 200 (uVp-p)

Differential Input Impedance > 5 MΩ

CMRR Monitor > 105 dB

Operation > 105 dB

Diagnosis > 85 dB

Electrode offset potential ±300mV

Leakage Current < 10 uA

Baseline Recovery < 3 S After Defi.

ECG Signal Range ±8 m V ( Vp-p )

Bandwidth Surgery 1 ~ 20 Hz

Monitor 0.5 ~ 40 Hz

Diagnostic 0.05 ~ 130 Hz

Calibration Signal 1 (mVp-p), Accuracy:5%

ST Segment Monitoring Range Measure and Alarm -2.0 ~ +2.0 mV

ARR Detecting Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2,BRADY, MISSED BEATS,

PNP, PNC,Alarm Available,Review Available

Respiration

Method Impedance between R-F(RA-LL)

Differential Input Impedance > 2.5 MΩ

Measuring Impedance Range 0.3~3 Ω

Base line Impedance Range 200~4 KΩ

Bandwidth 0.1~2.5Hz

Resp. Rate Measuring and Alarm Range

Adult 0 ~ 120 Brpm

Neo/Ped 0 ~ 150 Brpm

Resolution 1 Brpm

Accuracy ±2 Brpm

Apnea Alarm 10 ~ 40 S

NIBP

Method Oscillometric

Mode Manual, Auto, STAT

Measuring Interval in AUTO Mode 1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120, 180, 240,480 (Min)

Measuring Period in STAT Mode 5 Min

Pulse Rate Range 40 ~ 240 bpm

Alarm Type SYS, DIA, MEAN

Measuring and alarm range Adult Mode

SYS 40 ~ 270 mmHg

DIA 10 ~ 215 mmHg

MEAN 20 ~ 235 mmHg

Pediatric Mode

SYS 40 ~ 200 mmHg

DIA 10 ~ 150 mmHg

MEAN 20 ~ 165 mmHg

Neonatal Mode

SYS 40 ~ 135 mmHg

DIA 10 ~ 100 mmHg

MEAN 20 ~ 110 mmHg

Resolution 1mmHg

Accuracy Maximum Mean error ±5mmHg

Maximum Standard deviation ±8mmHg

Overpressure Protection Adult Mode 297±3 mmHg

Pediatric Mode 240±3 mmHg

Neonatal Mode 147±3 mmHg

SpO2

Measuring Range 0 ~ 100 %

Alarm Range 0 ~ 100 %

Resolution 1 %

Accuracy 70% ~ 100% 2 %

0% ~ 69% unspecified

Actualization intervalabout 1 Sec.

Alarm Delay 10 Sec.

Pulse Rate Measuring and Alarm Range 20~300 bpm

Resolution 1bpm

Accuracy ±3bpm

TEMP

Channel 2

Measuring and Alarm Range 0 ~ 50 ℃

Resolution 0.1 ℃

Accuracy ±0.2 ℃

Actualization intervalabout 1 Sec.

Average Time Constant < 10 Sec.

IBP

Label ART, PA, CVP, RAP, LAP, ICP, P1, P2

Measuring and alarm range ART 0 ~ 300 mmHg

PA -6 ~ 120 mmHg

CVP/RAP/LAP/ICP-10 ~ 40 mmHg

P1 / P2-10 ~ 300 mmHg

Press Sensor Sensitivity 5 uV/V/mmHg

Impedance 300-3000Ω

Resolution 1 mmHg

Accuracy ±2% or 1mmHg which is greater

Actualization interval about 1 secretary

Standard: ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature

Optional: Nellcor SpO2, EtCO 2, IBP, Thermal Recorder