Home
/
Categories
/
Health & Medical
/
Heart Rate Monitor
/
Portable PDT Laser
Portable PDT Laser
FOB Price
Korea (North)
Main Products : PDT, optics
910 Professor Research Bulding, 99, Daehak-ro, Yuseong-gu,, Daejeon
Portable PDT Laser Details
Model Number
Laxcell 2004
Place of Origin
Korea
Portable PDT Laser Introduce

Laxcell 2004 Portable Laser

Photodynamic Therapy

gentle treatment methods with enormous potential

PDT is minimally invasive treatment method based on the principle of selective light-induced tissue destruction.

Thermal relaxation time mode

Pulse radiation Burst radiation

The specification and characteristic

Electrical requirement
110/220-230VAC
Dimensions
400 x 500 x 200mm(W x D x H)
Weight
20kg
Laser beam
parameter
Material
Semiconductor diode
Max power
250mW
Wavelength
635nm
Beam delivery
Flexible light fiber
Continuous
Radiation total time 0 to 59min 59sec
Thermal Relaxtion
Time Mode
Pulse
Radiation total time 0 to 59min 59sec
Pulse ON time 0 to 599sec
Pulse OFF time 0 to 599sec
Burst Pulse
Radiation total time 0 to 59min 59sec
Pulse ON time 10 to 9990ms
Pulse OFF time 10 to 990ms
Duration ON time 0 to 599sec
Duration OFF time 0 to 599sec
Energy(J)
Auto-display a energy value calculated according as set power and time(pulse on, off time, duration on, off time and radiation total time)
Cooling system
Air-cooling system
Control
Air-cooling system
Electronic control
Microprocessor
Indicators
Touch-Screen
Menu mode
Touch-Screen for treatment parameters selection and modification from menu
Status
Ready mode, Radiation mode, Stop mode
Switch
Foot switch
Safety
Every person inlaser operation are must wear certificated safety foffles, warning light and labels equipped at the entrances

CW, Pulse, Burst Pulse Radiation Mode

Laxcell series adopt the three Radiation Mode of cw, Pulse, Burst Pulse type which is one of the most advantage in the world. Bio Optics designed to prevent skin burn due to the thermal effects and optimism of photodynamic therapy.

The importance faefors in photodynamic therapy are thermal relaxation time and oxygen(O2) recovery time that shown the figure1 and figure2

Thermal relaxation time prevent the skin burn due to the thermal effects whenever confineous wave radiation mode accumulate the photon energy.

Oxygen recovery time

In order to yield the more signet oxygen in tumor they need the recovery time to increasing of oxygen saturation in tumor. So Laxcell series can be select the pulse and burst pulse of radiation mode.

Adopt the guide program using the touch screen panel.

Automatic calculation algorithm of energy amount for the exposure time and output power at each radiation mode.

Portable compat, safety and easy to control.

Previous : Paraffin Bath (Paraffin Warmer) Next : Ultrasound