Model Number
DWA-3000A Residual Chlorine Analyzer
Residual Chlorine Analyzer On-Line System Introduce

= DWA-3000A RC Analyzer ( Real Time TREND ) =

Function / Feature :

Real Time TREND Analyzer Function Simple Operation by 8 Keypad Button Maximum 4-Relay contact - HH, H, L, LL Large Size of Graphical LCD & backlight RS-232C/DC Power Modem Interface Communication Isolated Output 0~20, 0~24, 4~20mA Selection DC Output Isolated DC/AC Output Transmission Water-jet, Air-jet, Ultrasonic Wave, and Medicinal fluid Cleaning of relay contact output Automatic/ Manual temperature compensation Automatic/ Manual calibration. Automatic cleaning control Function LOW-COST for user satisfaction

Application :

Water Treatment Plant Pool, Beverage Process Industrial Process: Food/Chemical/Pharmaceutical etc. Disinfection Treatment

Specification :

Model Name ; DWA-3000A RC Analyzer

Measurement Range ; 0~2 ppm,(mg) or User Spec

Power ; AC100V/AC220V 50/60Hz ±10% 3VA

Display ; Measurement Indication, Message Icon, Real time Trend Analysis Graph

Keypad ; Membrane Keypad 8 Keys

Temperature Range ; Temperature : -25°C ~ 70°C

Relative Humidity : Max. 90%(Non-condensing)

Accuracy ; ±1% of Full Scale

Repeatability Reproducibility ; ±1% of Full Scale

Response ; 120 sec (98% saturation)

Relay Output ; High-High, High, Low, Low-Low(4 Outputs)

Signal Output ; DC : Isolated 0~20, 0~24, 4~20mA_Option

Digital Interface : Isolated RS232C/DC POWER MODEM_Option

Condition ; Conductivity : Min. Over 100ã?²/cm pH : 6~8pH

Measurement Flow : Minimum 0~1

Sample Water Temperature : 0~40°C

Sensor Calibration ; Auto/Manual Temperature Compensation

Calibration Method ; Colorimetry Method by Colorimeter

Dimensions ; 240(W) x 180(H) x 115(D)mm

Environmental Rating ; IP65, Waterproof, Dustproof, Outdoor installation structure

Installation ; 2″Pipe Mounting, Panel Wall Mounting

Weight ; About 1.5Kg