Home
/
Categories
/
Electrical Equipment & Supplies
/
Generators
/
Diesel Generators
/
Simple Type 3 Phase Thyristor Power Regulator SCR3-LA
Simple Type 3 Phase Thyristor Power Regulator SCR3-LA
FOB Price 160 USD / Piece
MOQ
1 Piece
Port
NINGBO
China
Main Products : AC DC current-voltage switch-plate
NO.18,Baosheng Road,Songjiang District,Shanghai,China Shanghai, Shanghai
Simple Type 3 Phase Thyristor Power Regulator SCR3-LA Details
Model Number
SCR3-LA
Place of Origin
China
Supply Type
In-Stock Items
Condition
New
Output Type
AC Three Phase
Rated Current
25A, 40A, 75A, 90A, 120A
Rated Voltage
hree phase 380VAC(three-phase four-wire) 220VAC fan
Simple Type 3 Phase Thyristor Power Regulator SCR3-LA Introduce

Simple type 3 phase thyristor power regulator SCR3-LA Product Features

1.Linear shift phase control circuit has a good stability performance and high precision.

2.Modularization can stand high pressure and be more reliable.

3.The product integrated control system, power device and auxiliary power supply.

4.Adopted PID control keep temperature precise and stable.

Simple type 3 phase thyristor power regulator SCR3-LA Technical Parameters

Rated Voltage: Three phase 380VAC(three-phase four-wire) 220VAC fan

Rated Current: 25A, 40A, 75A, 90A, 120A

Output Module: shift phase output

The signals of control: 4-20mA,0-5VDC,0-10VDC(These three signals can be switchable). If you want to manually adjust by the potentiometer of 2-10K, please switch to 0-5VDC.

Environment Conditions:

Temperature: below 45°C

Humidity: below 90%RH

Simple type 3 phase thyristor power regulator SCR3-LA

Product Model

Product Type SCR3-LA
Rated Current 25A 40A 75A 90A 120A 
External Dimension
(mm)
W 100
L 110
H 145
Installation Dimension
(mm)
W 90
L 80

Simple type 3 phase thyristor power regulator SCR3-LA Operation Warning

1. The main circuit adopts three-phase four-wire input without requirement for phase sequence.

2. For SCR is a product with a high current, please keep in mind that terminals of R,S,T and U,V,W be locked tightly, or SCR will be burned by terminals’ heating.

3. When Y connection is used for three-phase load, the center of Y should be connected with zero line, if not so, relative equilibrium of the three-phase is required.

4. During the use of module, when the load power is more than 15KW, it's best to be equipped with proper radiator, and heat conducting silicon grease should be coated between radiator and SCR backboard with wind cooling.

5.

Module protection: Please use semi-conductive fast fuse for load over current.

Remark: When the working power is more than 15KW,please keep in mind that the radiator should be used frequently.