SPM520 Single Phase Bidirectional Energy Meter Details
Brand Name
Standardel
Model Number
SPM520
Place of Origin
China
Accuracy Class
0.5%
Dimensions
72x72x86mm
Measuring Current Range
5A
Measuring Voltage Range
110V/220V/380V
Operating Temperature
-20~70C
Communication
RS485
SPM520 Single Phase Bidirectional Energy Meter Introduce

1. General

SPM520 power analyzer is designed special for electrical detection system in the field of electric, of mining, of infrastructure, of intelligent buildings etc.. It may measure all the parameters on single phase, such as current, voltage, active power, reactive power, apparent power, frequency, power factor and active & reactive energies.

It has 3 red LED display and it may be installed in any insdustrial space. It also has 4 front keys and users may easily change display page and set network parameters by them. Every SPM520 is equipped RS485 interface to connect master device, such as PLC, data center computers.

2. Function

* With 3 high Red LED display, which may be well visible in any somber space;

* Measuring 9 parameters on single phase: IL, UL, Fr, P, Q, S, PF, import & export kWh, inductive & capacitive kvarh

* With RS485 interface to connect master device, slave address & baud rate may be programmable;

* Programmable CT, PT ratio and wiring mode, it may be used on different AC networks;

* With plug-in connectors, easy to wiring;

* With StandardeL PC software, the user may easily read and SPM520 data and program its parameters by computer.

3. Features

Technical Feature              Parameters 
Input Wiring 1P2L
Voltage Rating: AC 400V or 100V
Overload: 480V (continuous); 1000V during 10s                          
Consumption: < 1VA
Current Rating: AC 1A or 5A
Overload: 6A (continuous); 50A during 10s
Consumption: < 1VA
Frequency 45 ~ 65Hz
Precision 0.2%(U,I); 0.5% (F: 0.05Hz, kVarh: 1%)
Thermal drift <200ppm
Transformation ratio CT and PT ratio programmable
RS485 interface 3 cables RS485 (Modbus-RTU protocol)
Energy Impulse 2 impulse (open-collector) for kWh & kvarh
VCC<48V, Iz<50mA
Constant: 3600imp/kWh(/kvarh)
RealValue = ReadValue x PT x CT
Power supply AC/DC 85 ~ 265V; Consumption < 5VA
Standard EN61036, EN61010
Isolation 2kVAC/min ( input / output / power supply)
input / housing and output / housing >50M??
Environment Work Temperature: -20C ~ +55C
Storage Temperature: -20C ~ +70C
Relative humidity: 5% ~ 95% (no condensation)
Altitude: < 2500m