Specifications:
Rated voltage range: 10 to 100 and 160 to 400V
Capacitance tolerance range (25°C, 120Hz): 0 to 20%
Leakage current (uA): 0.02CV or 5mA, whichever is smaller (at 25°C, after five minutes)
C: Nominal capacitance (uF)
V: Rated voltage (V)
Dissipation factor (25°C and 120Hz): TTND shall not exceed the values shown in the table of standard ratings
Temperature stability (120Hz): Capacitance change
10 to 100V DC: Capacitance at -40°C shall not be less than 60% of the 25°C value
160 to 400V DC: Capacitance at -25°C shall not be less than 70% of the 25°C value
Load and shelf lifespan (85°C):
Time: 2,000 hours
Leakage current: Not more than specified value
Capacitance change: Within ±20% of initial value
Dissipation factor: Not more than 200% of specified value
After test: UR to be applied for 60 minutes, 24 to 48-hour before measurement
Suitable for switching power supply
Operating temperature range: -40 to 85 and -25 to 85°C