Home
/
Categories
/
Electrical Equipment & Supplies
/
Switches
/
Flow Switches
/
Water Flow Switch Measure Flow and Temperature, Relay / 4-20mA, Which Can Be Transmitted Remotely
Water Flow Switch Measure Flow and Temperature, Relay / 4-20mA, Which Can Be Transmitted Remotely
FOB Price 275 - 300 USD / Box
MOQ
1 Box
Port
Yantian
Lead Time
60 days for OEM, 7 days for ready goods
China
Main Products : flow switch, Temperature flow sensor, flow sensor
6 Xinmu Avenue, Xinmu community, Pinghu Street Shenzhen, Guangdong
Water Flow Switch Measure Flow and Temperature, Relay / 4-20mA, Which Can Be Transmitted Remotely Details
Brand Name
VOLKE
Model Number
FGI
Place of Origin
China
Supply Type
In-Stock Items
Condition
New
Color
Yellow
Media Type
Liquid
Water Flow Switch Measure Flow and Temperature, Relay / 4-20mA, Which Can Be Transmitted Remotely Introduce

FGI flow temperature integrated sensor can monitor the liquid flow and temperature in the pipeline in real time, provide flow 4-20mA signal and alarm switching value output, temperature 4-20mA signal and alarm switching value output, use digital led to display the fluid flow rate and temperature in real time, and set the alarm output through the meter, Realize the integrated monitoring function of temperature and flow in the pipeline. It is widely used in petrochemical, electric power, metallurgy, steel mills, papermaking, food and export processing, water treatment, battery factory and other industries.

Working principle of FGI flow switch:

FGI thermal conductivity flow switch is designed based on the principle of heat exchange.

The probe has built-in heating module and heat sensing module.The heat conduction of the flow switch is closely related to the flow rate of the medium,During measurement,the heat is generated by the heating module according to the working principle of the thermal conductivity flow switch.If there is no medium flow in the pipeline,the heat received by the heat sensing module is a fixed value;When a medium flows,the heat received by the heat sensing module will change with the flow rate of the medium.The heat sensing module converts the temperature difference signal into an electrical signal,and then converts it into the corresponding standard analog signal or contact signal output through the processor.The flow switch displays and controls the flow rate of the medium through this signal.

Its characteristics:The anti scaling coating of the probe can effectively prevent the adhesion of scale,rust and other dirt in the pipeline,and has stronger anti fouling ability.The full waterproof shell design is applicable to a wide range of pipe diameters.The set point can be adjusted arbitrarily.The high-pressure type can withstand pressure up to 60MPa.The indicator light directly displays the flow change.Effectively prevent entanglement.

FGI thermal conductivity flow controller is equipped with 3-digit digital l e d to display the current pipeline flow. There are three keys on the panel, which can easily set the flow alarm contact. FGH thermal conductivity flow controller can have two alarm contact outputs and one 4-20 mA

FGI flow temperature integrated sensor characteristics:

1. The temperature transmission controller is integrated with the flow switch.

2. Digital LED displays flow and temperature.

3. Intelligent flow display and alarm contact.

4. Temperature intelligent display and alarm contact.

5. Flow and temperature 4-20mA output can be switched.

Technical parameter:
Flow parameters
Measuring rangewater: 0.03 ~1.5 m/s
Oil: 0.03 ~3 m/s
Display3-digit LED digital display
Switching timeON: ≥ 5 s (1 ~ 1 3 s); OFF :≥5 s(1 ~1 5 s
Outputone alarm contact, 4 - 20 m a (settable)
Contact capacity0.15A / 125 VAC, 0.5A / 30 VDC
Insulation impedance 50 MΩ at 100 V D C
Alarm contact typerelay, NPN, PNP
Measurement range- 10 ~ 80 ºC, customized
Temperature parameters
Display3-digit LED digital display
Outputone alarm contact, 4 - 20 m a (settable)
Contact capacity0.15A / 125 VAC, 0.5A / 30 VDC
Insulation impedance50 MΩ at 100 V D C
Alarm contact typerelay, NPN, PNP
Other parameters
Environmental conditions- 2 0 ~8 5ºC,≤8 5 % RH
Protection classIP67
Power consumption3W (24 VDC)
Shell materialPP
Interface modeM 1 8 X 1 . 5 internal thread
Environmental conditions- 2 0 ~8 5ºC,≤8 5 % R H
Probe material304 stainless steel

Our competitive brands are as follows: e+h,turck,ema,ifm,ege,afm,omega

We can replace the following models:

FCI-D03A4-NA-H1141/M12;FCI-D03A4-NA-H1141/M16;FCI-D04A4P-AP8X-H1141;FCI-D04A4P-ARX-H1140;FCI-D04A4P-LIX-H1141;FCI-D09A4-NA-H1141/M16;FCI-D10A4P-AP8X-H1141;FCI-D10A4P-ARX-H114;FCI-D10A4P-LIX-H1141;FCI-D10A4P-NA-H1141;FCI-D15A4P-AP8X-H1141;FCI-D15A4P-ARX-H1140;FCI-D15A4P-LIX-H1141;FCI-D20A4P-AP8X-H1141;FCI-D20A4P-ARX-H1140;FCI-D20A4P-LIX-H1141;FCI-TCD04A4P-AP8X-H1141;FCI-TCD04A4P-ARX-H1140;FCI-TCD04A4P-LIX-H1141 FCS-50A4-AP8X-H1141/D014;FCS-50A4-NA/D014;FCS-68A4-NA/D003;FCS-68A4-NA/D011;FCS-G1/2A4-AN8X-H1141;FCS-G1/2A4-AP8X-H1141;FCS-G1/2A4-AP8X-H1141/L080;FCS-G1/2A4-NA;FCS-G1/2A4-NA/AL065;FCS-G1/2A4-NA/D100;FCS-G1/2A4-NA/L080;FCS-G1/2A4-NA/L120;FCS-G1/2A4-NAEX;FCS-G1/2A4-NAEX/D100;FCS-G1/2A4-NAEX/L065/D100;FCS-G1/2A4-NAEX0;FCS-G1/2A4-NAEX0/L065;FCS-G1/2A4-NAEX0-H1141;FCS-G1/2A4-NAEX-H1141;FCS-G1/2A4-NA-H1141;FCS-G1/2A4-NA-H1141/L080;FCS-G1/2A4-NA-H1141/L120;FCS-G1/2A4P-AP8X-H1141;FCS-G1/2A4P-AP8X-H1141/L080;FCS-G1/2A4P-LIX-H1141;FCS-G1/2A4P-LIX-H1141/D037;FCS-G1/2A4P-VRX/230VAC;FCS-G1/2A4P-VRX/24VDC;FCS-G1/4A4-AP8X-H1141;FCS-G1/4A4-ARX-H1140;FCS-G1/4A4P-AP8X-H1141;FCS-GL1/2A2-NA/A;FCS-GL1/2A2-NA-H1141/A;FCS-GL1/2A2P-AP8X-H1141/A;FCS-GL1/2A2P-LIX-H1141/A;FCS-GL1/2A2P-VRX/230VAC/A; FCS-GL1/2A2P-VRX/24VDC/A;FCS-GL1/2A4-AP8X-H1141;FCS-GL1/2A4-AP8X-H1141/D090;FCS-GL1/2A4-NA;FCS-GL1/2A4-NA/D100;FCS-GL1/2A4-NAEX;FCS-GL1/2A4-NAEX/A;FCS-GL1/2A4-NAEX/A/D100;FCS-GL1/2A4-NAEX/D100;FCS-GL1/2A4-NAEX0;FCS-GL1/2A4-NAEX0/A;FCS-GL1/2A4-NAEX0-H1141;FCS-GL1/2A4-NAEX0-H1141/A;FCS-GL1/2A4-NAEX-H1141;FCS-GL1/2A4-NAEX-H1141/A;FCS-GL1/2A4-NA-H1141;FCS-GL1/2A4P-AP8X-H1141;FCS-GL1/2A4P-LIX-H1141;FCS-GL1/2A4P-VRX/230VAC;FCS-GL1/2A4P-VRX/24VDC;FCS-K20-AP8X;FCS-K20-LIX;FCS-M18-AP8X;FCS-M18-AP8X/D041;FCS-M18-LIX;FCS-N1/2A4-AP8X-H1141;FCS-N1/2A4-NA;FCS-N1/2A4-NA/D100;FCS-N1/2A4-NAEX;FCS-N1/2A4-NAEX/D100;FCS-N1/2A4-NAEX0;FCS-N1/2A4-NAEX0-H1141;FCS-N1/2A4-NAEX-H1141;FCS-N1/2A4-NA-H1141;FCS-N1/2A4P-AP8X-H1141;FCS-N1/2A4P-AP8X-H1141/L120;FCS-N3/4A4-NA-H1141

FAQ:

1. Q: Are you manufacturer or trading company?

A: We are manufacturer which focuses on sensor for 10 years.

2. Q: What's your quality control system?

A: MC, ISO9001, CE Certificated.

3. Q: What is the warranty of your products?

A: Our warranty time is 18 months after shipment.

4. Q: What is lead time of your product?

A: Normally, our factory lead time is within 10~15 working days for products without customization. You can also check lead time detail with our sales depending on different items.

5. Q: Do you provide customized products?

A: Yes, we can laser mark your logo on products; OEM and ODM customization are welcomed.

6. Q: What is your MOQ?

A: We have no MOQ limit, small quantity order is acceptable.

7. Q: What's the transport?

A: Express such as DHL, FedEx, TNT, UPS for freight prepaid; and we can also use your own courier account to do the freight collect. For more goods we can arrange by air or by Sea.

8. Q: What is your terms of payment ?

A: We could accept T/T, Paypal, WU.

For more information, please contact us~

Previous : V-15-1C25 Basic Plunger Model Micro Switch Next : V10SS Stainless Steel Paddle Flow Switch
Copyright 2023-2024 - www.globalbiz8.com All Rights Reserved