Home
/
Categories
/
Measurement & Analysis Instruments
/
Other Measuring & Analysing Instruments
/
Winner 2009 Wet Large-range Laser Particle Size Analyzer Particle Size Analyzer
Winner 2009 Wet Large-range Laser Particle Size Analyzer Particle Size Analyzer
FOB Price 28578 USD / Set
MOQ
1 Set
Port
qingdao
Lead Time
7days
China
Main Products : particle size analyzer
Building F,University Science Industry Park,Shunhua Road,High-tech Distriict Jinan, Shandong
Winner 2009 Wet Large-range Laser Particle Size Analyzer Particle Size Analyzer Details
Brand Name
Winner
Model Number
Winner 2009
Place of Origin
China
Supply Type
In-Stock Items
Condition
New
Color
White
Measure range
001m 2000m
Light source
Semiconductor laser
Sample cuvette
1-4mL
Winner 2009 Wet Large-range Laser Particle Size Analyzer Particle Size Analyzer Introduce

Product Description Winner2009B full automatic wet laser particle size analyzer adopt MIE scattering principle, measure size is from 0.01μm to 2000μm, Which offer reliable and repeatable particle size analysis for a diverse range of applications.It use dual-beam& multiple spectral detection systems and side light scatter test technology to significantly improve precision and performance of test, on behalf of the domestic advanced level in the field.

Main Features (1) Particle size analyzer configuration Award-winning patent-optical path design The patented technology of concentrated light Fourier transform light makes scattered light not limited by the lens aperture. The dual-spectrum design enables the accuracy to reach 0.01μm to 2000μm/1200μm. The dual-laser orthogonal light uses semiconductor auxiliary lasers to extend the test angle from 45 degrees to 135 degrees to ensure reception of signals from all angles. (2) Expand size range The measurement range of Winner2008A/B has been greatly extended to 0.01μm, which is especially suitable for users with small samples. The test results of sub-micron particles have reached the international level. (3) The particle size analyzer adopts a fully automatic built-in wet dispersion system The instrument is reasonably integrated with ultrasonic dispersion, mechanical stirring and circulation channels to ensure uniform dispersion and distribution of particles during the test process, effectively avoiding uneven distribution and large particle deposition caused by too long pipelines in the external dispersion system to ensure test results. accuracy. (4) The particle size analyzer adopts intelligent operation mode It has an intelligent automatic operation mode to realize one-click testing. Just add samples according to the prompts and click "Test". All processes including water supply, dispersion, circulation, testing, cleaning, data recording, data analysis, saving and printing are automatically completed, which not only reduces It reduces the detection workload and eliminates the interference of human factors, further improving the accuracy and authenticity of the detection results. (5) The particle size analyzer adopts an automatic optical path alignment system The precision of the four hybrid stepper motors in the optical component automation system has a microscopic precision of 0.01μm, which keeps the instrument's optical path in the best state, eliminating the trouble and difficulty of manually adjusting the optical path, and also enhances accuracy and stability. Test Results. (6) Authoritative calibration method National standard materials are used for calibration throughout the entire testing range, and the instrument only needs to be calibrated once a year. The calibration method is simple and fast. (7) The particle size analyzer adopts unconstrained free fitting patented technology Winner's original unconstrained free fitting patented technology allows particle size analysis to be free from any functional constraints and truly reflects particle size distribution.

Specification Model Name Winner2009B Standard ISO13320-1:1999, GB/T19077.1-2008, Q/JWN001-2009 Principle MIE scattering principle Measuring Range 0.01μm-2000μm 0.01μm-1200μm Channels Number 127 120 (different photo detectors & optical light path) Accuracy error ≤0.5% (Deviation of D50 on national standard sample) Repeatability error ≤0.5% (Deviation of D50 on national standard sample ) Light source High performance He-Ne Laser (λ= 632.8nm, P>2MW) Lifetime>25000hours Dispersion Method Ultrasonic Frequency:40KHz Power:35W, Time: ≥1S ,Anti-dry function Stir Revolutions Speed: 0-3000RPM (Adjustable) Circulate Rated Flow:8L/min Rated Power:10W Sample Pool Volume:350mL Micro- Sample Pool Volume: 10mL ( Available) Operation Mode Full automatic/ manual control, freely choose Resolution Free distribution truly reflect particle size distribution Optical bench alignment system Japan Canon lens, Full automatic,precision is up to 0.1um Software function Analysis mode Free Distribution, R-R Distribution, Logarithm Normal Distribution, Mesh number classification etc. Statistic Method Volume Distribution, Quantity Distribution Statistic Comparison Several Testing Results of samples Different batches of samples testing result, Samples before and after processing, Test result of samples in different time. User-defined Analysis Figure out percentage according to the particle size Figure out particle size according to the percentage Figure out percentage according to the particle size range Meet demands of representation of particle test in different industries Test Report Word, Excel,Photo( Bmp), Text etc Multiple-language Support Multiple language Support Intelligent operation Automatically control water inflow, dispersion,test and analysis.Better Repeatability after remove human-factor Testing speed <2min/time Outer dimension Host machine :L120cm*W37cm*H56cm Wet dispersion box: L44.2cm*W28cm*H34.2cm 58Net weight 58kg+15kg

Quality Assurance 1. Strictly conforming to ISO9001-2000 quality management system. 2. Strict control from purchasing materials, process inspection to final particle size distribution test. 3. QC department to execute quality control regulations. 4.Only qualified components will be assembled and total laser particle size analyzer must be inspected completely before sale. 5.Laser particle size analyzer will be processed preventing -shake test before delivery. After Sale Service 1. Provide operation demonstration video. 2. Provide free installation and training services. 3. The warranty period is 1 year after receipt of the goods, and technical support is provided for life. 4. If repair parts are provided, we will provide parts at favorable prices, only charge cost prices, and provide long-term maintenance.

Previous : LCD-82 Dust Analyzer Next : Shaker for 2plates