ZR-120WH CO2 laser PSU
Feature:
1. The 120w Laser Power Source has good compatibility : This HV Laser Power Source can drive EFR,Yongli, SPT,Weiju and other brand 1450mm,1400mm or 1500mm 120Watt glass laser tube,besides this feature, the Hv Laser Power Source also has strong adaptability and fast response, engraving or cutting benefits good effect.
2.The analog signal Laser Power Source has very good protection feature: The 120watt Laser Power Source has open circuit protection to make this HV Laser Power Source works for a short time in the open state, so as to make it avoid the laser tube broken.
3.This 220vLaser Power Source has stable working performance: Each 120w Laser Power Source has been much more testing procedures and under full load high temperature (52~55 degrees celsius) 24 hours of aging, which ensure the stability of each CO2 laser power source.
4.The laser power control is simple, the 220v Laser Power Source can uses 0-5V analog signal or PWM signal for laser power control.
5.This analog signal Laser Power Source has easy control: The 120w Laser Power Source uses high or low level for control. The use of TTL-level control can realize start and stop quickly. At the same time the HV Laser Power Source has a protection switch, testing is made by external water and ventilation
6.The 120w Laser Power Source selects ordinary H/L/P/G/IN/5V port to receive control signal. And black steel outside shell is used on this analog signal Laser Power Source.
Specification
Input |
Input voltage |
AC220V ±10% (AC110V specified while order) |
||
AC frequency |
47~440HZ |
|||
Maximum input power |
820W |
|||
Maximum input current |
3.7A |
|||
Output |
Maximum output voltage |
35KV |
||
Maximum output current |
35mA (depending on the laser tubes of different manufacturers) |
|||
Efficiency |
More than 90% (Full load) |
|||
Response speed |
Not more than 1ms |
|||
Control lnterace |
TTL multilevel switching control,effective level can be high and low selection (see control wining diagram) |
|||
Insulation |
lnput-output |
AC 1500V 1 minutes not more than 10mA |
||
lnput-shell |
AC 1500V 1 minutes not more than10mA |
|||
Output-shell |
Connection |
|||
Open Circuit Protection |
Can be short circuit (requires a good grounding shell,while avoiding the positive electrode and the shell between the arc) |
|||
Environmental Requested |
Working temperature |
-10 ℃~50 ℃ |
||
Storage of temperature |
-20 ℃~75 ℃ |
|||
Relative Humidity |
Maximum 85%RH (non-condensing) |
|||
Altitude |
100,000 feet of work 200,000 feet of storage,dose not work |
|||
Cooling methods |
Forced air cooling (fan cooling) |
|||
Dimensions (LxWxH) |
335mmx205mmx100mm |
|||